IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v8y2011i6p1914-1922d12598.html
   My bibliography  Save this article

Environmental Surveillance. An Additional/Alternative Approach for Virological Surveillance in Greece?

Author

Listed:
  • Petros Kokkinos

    (Environmental Microbiology Unit, Department of Public Health, Medical School, University of Patras, Patras, GR 26504, Greece)

  • Panos Ziros

    (Environmental Microbiology Unit, Department of Public Health, Medical School, University of Patras, Patras, GR 26504, Greece)

  • Danai Meri

    (Environmental Microbiology Unit, Department of Public Health, Medical School, University of Patras, Patras, GR 26504, Greece)

  • Sevasti Filippidou

    (Environmental Microbiology Unit, Department of Public Health, Medical School, University of Patras, Patras, GR 26504, Greece)

  • Stella Kolla

    (Department of Molecular Biology and Genetics, Democritus University of Thrace, Alexandroupolis, GR 68100, Greece)

  • Alexis Galanis

    (Department of Molecular Biology and Genetics, Democritus University of Thrace, Alexandroupolis, GR 68100, Greece)

  • Apostolos Vantarakis

    (Environmental Microbiology Unit, Department of Public Health, Medical School, University of Patras, Patras, GR 26504, Greece)

Abstract

The detection of viruses in the sewage of an urban city by nucleic acid amplification techniques allows the identification of the viral strains that are circulating in the community. The aim of the study was the application of such detection which gives useful data on the distribution, spread, and frequency of these viruses, supporting epidemiological studies of the related viral infections. A two year (2007–2009) survey was conducted in order to evaluate the presence of human adenoviruses (hAdV), hepatitis A viruses (HAV), hepatitis E viruses (HEV), noroviruses (NoV), and human polyomaviruses (hPyV) in sewage samples collected from the inlet of a municipal biological wastewater treatment plant located in southwestern Greece. PCR methods were used for this survey. In total, viruses have been detected in 87.5% (42/48) of the analyzed sewage samples. Analytically, DNA viruses, hAdVs and hPyVs have been detected in 45.8% (22/48) and 68.8% (33/48) of the samples, respectively. As it concerns RNA viruses, HAV was detected in 8.3% (4/48), NoVs in 6.3% (3/48), while HEV has not been detected at all. After sequencing, AdVs were typed as Ad8, Ad40 and Ad41, while both JC and BK hPyVs have been recognized. All NoVs have been identified as GII4, while HAV was typed as genotype IA. Similar long-term studies could be undertaken in countries such as Greece in order to offer a valuable and complementary tool to current problematic epidemiological surveillance systems. This study demonstrates the advantages of environmental surveillance as a tool to determine the epidemiology of viruses circulating in a given community. To our knowledge this was the first of its kind study performed in Greece in order to establish this new way of surveillance.

Suggested Citation

  • Petros Kokkinos & Panos Ziros & Danai Meri & Sevasti Filippidou & Stella Kolla & Alexis Galanis & Apostolos Vantarakis, 2011. "Environmental Surveillance. An Additional/Alternative Approach for Virological Surveillance in Greece?," IJERPH, MDPI, vol. 8(6), pages 1-9, June.
  • Handle: RePEc:gam:jijerp:v:8:y:2011:i:6:p:1914-1922:d:12598
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/8/6/1914/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/8/6/1914/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:8:y:2011:i:6:p:1914-1922:d:12598. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.