Author
Listed:
- Ashura Bakari
(Suntreso Government Hospital, Ghana Health Service, Kumasi AK-039, Ghana)
- Ann V. Wolski
(Department of Emergency Medicine, College of Medicine, University of Cincinnati, Cincinnati, OH 45221, USA)
- Benjamin Otoo
(Suntreso Government Hospital, Ghana Health Service, Kumasi AK-039, Ghana)
- Rexford Amoah
(Suntreso Government Hospital, Ghana Health Service, Kumasi AK-039, Ghana)
- Emmanuel K. Nakua
(Department of Epidemiology and Biostatistics, School of Public Health, Kwame Nkrumah University of Science and Technology, Kumasi AK-039, Ghana)
- Jacob Jacovetty
(Department of Epidemiology, School of Public Health, University of Michigan, Ann Arbor, MI 48109, USA)
- Elizabeth Kaselitz
(Department of Learning Health Sciences, University of Michigan Medical School, Ann Arbor, MI 48109, USA)
- Sarah D. Compton
(Department of Obstetrics & Gynecology, University of Michigan Medical School, Ann Arbor, MI 48109, USA)
- Cheryl A. Moyer
(Department of Learning Health Sciences, University of Michigan Medical School, Ann Arbor, MI 48109, USA
Department of Obstetrics & Gynecology, University of Michigan Medical School, Ann Arbor, MI 48109, USA)
Abstract
Background: Neonatal jaundice (NNJ) remains a leading cause of newborn mortality in much of sub-Saharan Africa. We sought to examine the validity of using a hand-held icterometer as a screening tool to determine which newborns need further assessment. Additionally, we sought to assess the feasibility of its use among mothers. Methods: We recruited and trained healthcare workers at one large district hospital in Ghana to use a hand-held icterometer known as the Bili-Ruler TM . We recruited mothers of 341 newborns aged 0 to 2 weeks at the same hospital. Mothers watched a standardized training video, after which they blanched the skin of the newborn’s nose and compared it with the yellow shades numbered one to six on the icterometer. Each newborn was also assessed with a transcutaneous bilirubin meter (TCB). Research assistants and health care workers screened the same newborns, recorded their scores separately, and were blinded to each other’s readings. In the second phase of this study, we recruited 100 new mothers to take the Bili-Ruler home with them, instructing them to check their newborns twice daily. We interviewed them 1–2 weeks later to determine the acceptability and feasibility of its use. Results: Out of 341 newborns screened, 20 had elevated TCB indicative of hyperbilirubinemia. Healthcare workers’ Bili-Ruler ratings had a strong and significant correlation with TCB scores, as did the ratings of researchers and mothers. When comparing Bili-Ruler scores against TCB, sensitivity across all three raters was 80% (95% CI 75.6–84.3), specificity ranged from 61.1% (healthcare providers) to 66.7% (researchers), positive predictive value ranged from 11.4% (healthcare providers) to 13.0% (researchers), and negative predictive value was 98.0% or higher across all raters. Area under the ROC curve ranged from 0.71 for healthcare providers to 0.73 for researchers. Mothers AUC was 0.72. In terms of acceptability and feasibility, the Bili-Ruler was widely accepted by the mothers and family. In total, 98% of mothers reported using it, and 90.8% used it 3 or more days in the first week after birth. Moreover, 89.8% used it more than twice per day. Conclusions: A hand-held, low-tech icterometer is an important potential mechanism for improving early jaundice identification in low-resource settings. Further studies using larger sample sizes with a higher prevalence of hyperbilirubinemia are warranted.
Suggested Citation
Ashura Bakari & Ann V. Wolski & Benjamin Otoo & Rexford Amoah & Emmanuel K. Nakua & Jacob Jacovetty & Elizabeth Kaselitz & Sarah D. Compton & Cheryl A. Moyer, 2025.
"Using a Hand-Held Icterometer to Screen for Neonatal Jaundice: Validation, Feasibility, and Acceptability of the Bili-Ruler TM in Kumasi, Ghana,"
IJERPH, MDPI, vol. 22(1), pages 1-14, January.
Handle:
RePEc:gam:jijerp:v:22:y:2025:i:1:p:96-:d:1565122
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:22:y:2025:i:1:p:96-:d:1565122. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.