IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v20y2023i7p5348-d1112667.html
   My bibliography  Save this article

Simulation on Heat Transfer and Emergency Protection of Tanks in a Tank Farm under Fire Scenario

Author

Listed:
  • Yingwei Bao

    (College of Environment and Safety Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China)

  • Feng Zhang

    (College of Environment and Safety Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China)

  • Jiaji Cheng

    (College of Environment and Safety Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China)

  • Yapeng Wang

    (College of Environment and Safety Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China)

  • Yu Guan

    (College of Environment and Safety Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China)

  • Junjie Ren

    (College of Environment and Safety Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China)

  • Fangbo Jin

    (College of Environment and Safety Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China)

  • Yunfei Cheng

    (College of Environment and Safety Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China)

  • Weilun Xie

    (College of Environment and Safety Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao 266042, China)

Abstract

It is very important to understand the heat transfer process between storage tanks in a tank farm under a fire scenario, which is one of the key factors in determining the consequences of accident development. In this paper, a CFD simulation is used to study the heat transfer process and emergency protection of tanks under a fire scenario. The simulated results show that the changes in wind speed can affect the heat transfer of the tank farm. The highest temperature of the tanks at 5.3 m/s (wind speed) is 1432 K, while the highest temperature at 17.1 m/s (wind speed) is 1556 K. At the same time, the changes in wind direction can also affect the heat transfer of the tank farm. For the 45° east by north (wind direction), almost all tanks in the tank farm are affected by the fire. When the water curtain was applied as an emergency protection measure, the simulated highest temperature of the tanks decreased to 779 K (the cooling water intensity 6 L/min·m 2 ), while the highest temperature of the tanks was 1432 K without water curtain protection under the actual fire conditions. The simulated highest temperature of the tanks decreased to 671 K when the emergency thermal insulation coating was sprayed on the surface of the tanks, which can effectively protect the adjacent tanks from being destroyed.

Suggested Citation

  • Yingwei Bao & Feng Zhang & Jiaji Cheng & Yapeng Wang & Yu Guan & Junjie Ren & Fangbo Jin & Yunfei Cheng & Weilun Xie, 2023. "Simulation on Heat Transfer and Emergency Protection of Tanks in a Tank Farm under Fire Scenario," IJERPH, MDPI, vol. 20(7), pages 1-18, March.
  • Handle: RePEc:gam:jijerp:v:20:y:2023:i:7:p:5348-:d:1112667
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/20/7/5348/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/20/7/5348/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:20:y:2023:i:7:p:5348-:d:1112667. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.