IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v20y2023i4p2904-d1060555.html
   My bibliography  Save this article

The PreserFlo MicroShunt in the Context of Minimally Invasive Glaucoma Surgery: A Narrative Review

Author

Listed:
  • Emil Saeed

    (Department of Ophthalmology, Medical University of Bialystok, Kilinskiego 1 STR, 15-089 Bialystok, Poland)

  • Kinga Gołaszewska

    (Department of Ophthalmology, Medical University of Bialystok, Kilinskiego 1 STR, 15-089 Bialystok, Poland)

  • Diana Anna Dmuchowska

    (Department of Ophthalmology, Medical University of Bialystok, Kilinskiego 1 STR, 15-089 Bialystok, Poland)

  • Renata Zalewska

    (Department of Ophthalmology, Medical University of Bialystok, Kilinskiego 1 STR, 15-089 Bialystok, Poland)

  • Joanna Konopińska

    (Department of Ophthalmology, Medical University of Bialystok, Kilinskiego 1 STR, 15-089 Bialystok, Poland)

Abstract

Recently, the quest for novel glaucoma surgical techniques and devices has been underway. Trabeculectomy remains the gold standard, but it requires the implantation of glaucoma drainage devices and frequent follow-ups, and it also carries a high risk of serious complications. The need for less invasive and safer procedures has led to the development of minimally invasive glaucoma surgery (MIGS), particularly for patients with mild–to–moderate disease. Among them, minimally invasive bleb surgery seems to be effective in classical glaucoma surgery, while maintaining MIGS benefits. The relatively new PreserFlo ® MicroShunt (Santen, Osaka, Japan) is registered in Europe. It was released in 2019 for the treatment of patients with early–to–advanced open-angle glaucoma, where intraocular pressure (IOP) remains uncontrolled while on maximum tolerated medication and/or where glaucoma progression warrants surgery. This review focuses on the place of the PreserFlo MicroShunt, characterized by ab externo implantation, among MIGS procedures, discussing its advantages and disadvantages. The mechanisms of action, technical aspects, efficacy, and safety issues are summarized. The surgical technique, its efficacy, and safety profile are described, and directions for future studies are indicated. The PreserFlo MicroShunt ensures a high safety profile, minimal anatomical disruption, meaningful IOP-lowering effect, and ease of use for patients and physicians.

Suggested Citation

  • Emil Saeed & Kinga Gołaszewska & Diana Anna Dmuchowska & Renata Zalewska & Joanna Konopińska, 2023. "The PreserFlo MicroShunt in the Context of Minimally Invasive Glaucoma Surgery: A Narrative Review," IJERPH, MDPI, vol. 20(4), pages 1-15, February.
  • Handle: RePEc:gam:jijerp:v:20:y:2023:i:4:p:2904-:d:1060555
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/20/4/2904/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/20/4/2904/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Emil Saeed & Renata Zalewska & Joanna Konopińska, 2022. "Early Complications and Results of Preserflo MicroShunt in the Management of Uncontrolled Open-Angle Glaucoma: A Case Series," IJERPH, MDPI, vol. 19(14), pages 1-12, July.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.

      Corrections

      All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:20:y:2023:i:4:p:2904-:d:1060555. See general information about how to correct material in RePEc.

      If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

      If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

      If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

      For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

      Please note that corrections may take a couple of weeks to filter through the various RePEc services.

      IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.