IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v19y2022i5p2942-d762992.html
   My bibliography  Save this article

Effects of Extended Viewing Distance on Accommodative Response and Pupil Size of Myopic Adults by Using a Double-Mirror System

Author

Listed:
  • Shu-Yuan Lin

    (Ph.D. Program in Medical Biotechnology, National Chung Hsing University, Taichung 402, Taiwan)

  • Hui-Rong Su

    (Department of Optometry, Chung Shan Medical University, Taichung 402, Taiwan)

  • Chen-Cheng Lo

    (Department of Optometry, Chung Shan Medical University, Taichung 402, Taiwan)

  • Shang-Min Yeh

    (Department of Optometry, Chung Shan Medical University, Taichung 402, Taiwan
    Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung 402, Taiwan)

  • Chi-Hung Lee

    (Department of Electrical Engineering, Feng Chia University, Taichung 407, Taiwan)

  • Richard Wu

    (College of Optometry and Visual Science, Pacific University, Forest Grove, OR 97126, USA
    Brighten Optix Research and Development Center, Taipei 111, Taiwan)

  • Fen-Chi Lin

    (Department of Ophthalmology, Kaohsiung Armed Forced General Hospital, Kaohsiung 802, Taiwan
    These authors contributed equally to this work.)

  • Yen-Wei Chu

    (Institute of Genomics and Bioinformatics, National Chung Hsing University, Taichung 402, Taiwan
    Institute of Molecular Biology, National Chung Hsing University, Taichung 402, Taiwan
    Agricultural Biotechnology Center, National Chung Hsing University, Taichung 402, Taiwan
    Biotechnology Center, National Chung Hsing University, Taichung 402, Taiwan)

  • Shuan-Yu Huang

    (Department of Optometry, Chung Shan Medical University, Taichung 402, Taiwan
    Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung 402, Taiwan
    These authors contributed equally to this work.)

Abstract

Purposes: This study discussed the accommodative response and pupil size of myopic adults using a double-mirror system (DMS). The viewing distance could be extended to 2.285 m by using a DMS, which resulted in a reduction and increase in the accommodative response and pupil size, respectively. By using a DMS, the reduction of the accommodative response could improve eye fatigue with near work. Method: Sixty subjects aged between 18 and 22 years old were recruited in this study, and the average age was 20.67 ± 1.09. There were two main steps in the experimental process. In the first step, we examined the subjects’ refraction state and visual function, and then fitted disposable contact lenses with a corresponding refractive error. In the second step, the subjects gazed at an object from a viewing distance of 0.4 m and at a virtual image through a DMS, respectively, and the accommodative response and pupil size were measured using an open field autorefractor. Results: When the subjects gazed at the object from a distance of 0.4 m, or gazed at the virtual image through a DMS, the mean value of the accommodative response was 1.74 ± 0.43 or 0.16 ± 0.47 D, and the pupil size was 3.98 ± 0.06 mm or 4.18 ± 0.58 mm, respectively. With an increase in the viewing distance from 0.4 m to 2.285 m, the accommodative response and pupil size were significantly reduced about 1.58 D and enlarged about 0.2 mm, respectively. For three asterisk targets of different sizes (1 cm × 1 cm, 2 cm × 2 cm, and 3 cm × 3 cm), the mean accommodative response and pupil size through the DMS was 0.19 ± 0.16, 0.27 ± 0.24, 0.26 ± 0.19 D; and 4.20 ± 1.02, 3.94 ± 0.73, 4.21 ± 0.57 mm, respectively. The changes of the accommodative response and pupil size were not significant with the size of the targets ( p > 0.05). In the low or high myopia group, the accommodative response of 0.4 m and 2.285 m was 1.68 ± 0.42 D and 0.21 ± 0.48 D; and 1.88 ± 0.25 D and 0.05 ± 0.40 D, respectively. The accommodative response was significantly reduced by 1.47 D and 1.83 D for these two groups. The accommodative microfluctuations (AMFs) were stable when a DMS was used; on the contrary, the AMFs were unstable at a viewing distance of 0.4 m. Conclusions: In this study, the imaging through a DMS extended the viewing distance and enlarged the image, and resulted in a reduction in the accommodative response and an increase in the pupil size. For the low myopia group and the high myopia group, the accommodative response and pupil size were statistically significantly different before and after the use of the DMS. The reduction of the accommodative response could be applied for the improvement of asthenopia.

Suggested Citation

  • Shu-Yuan Lin & Hui-Rong Su & Chen-Cheng Lo & Shang-Min Yeh & Chi-Hung Lee & Richard Wu & Fen-Chi Lin & Yen-Wei Chu & Shuan-Yu Huang, 2022. "Effects of Extended Viewing Distance on Accommodative Response and Pupil Size of Myopic Adults by Using a Double-Mirror System," IJERPH, MDPI, vol. 19(5), pages 1-10, March.
  • Handle: RePEc:gam:jijerp:v:19:y:2022:i:5:p:2942-:d:762992
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/19/5/2942/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/19/5/2942/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Sun-Mi Park & Byeong-Yeon Moon & Sang-Yeob Kim & Dong-Sik Yu, 2019. "Diurnal variations of amplitude of accommodation in different age groups," PLOS ONE, Public Library of Science, vol. 14(11), pages 1-13, November.
    2. Shang-Min Yeh & Chen-Cheng Lo & Chi-Hung Lee & Yu-Jung Chen & Feng-Chi Lin & Shuan-Yu Huang, 2021. "Reduction in Accommodative Response of Schoolchildren by a Double-Mirror System," IJERPH, MDPI, vol. 18(19), pages 1-9, September.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.

      Corrections

      All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:19:y:2022:i:5:p:2942-:d:762992. See general information about how to correct material in RePEc.

      If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

      If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

      If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

      For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

      Please note that corrections may take a couple of weeks to filter through the various RePEc services.

      IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.