Author
Listed:
- Giulio Pagliuca
(Otolaryngology University Unit, Santa Maria Goretti Hospital, 04100 Latina, Italy)
- Veronica Clemenzi
(Department of Sensorial Organs, ENT Section, “Sapienza” University of Rome, 04100 Rome, Italy)
- Andrea Stolfa
(Department of Sensorial Organs, ENT Section, “Sapienza” University of Rome, 04100 Rome, Italy)
- Salvatore Martellucci
(Otolaryngology University Unit, Santa Maria Goretti Hospital, 04100 Latina, Italy)
- Antonio Greco
(Department of Sensorial Organs, ENT Section, “Sapienza” University of Rome, 04100 Rome, Italy)
- Marco de Vincentiis
(Department of Oral and Maxillofacial Sciences, “Sapienza” University of Rome, 00161 Rome, Italy)
- Andrea Gallo
(Otolaryngology University Unit, Santa Maria Goretti Hospital, 04100 Latina, Italy
Department of Sensorial Organs, ENT Section, “Sapienza” University of Rome, 04100 Rome, Italy)
Abstract
Background: Continuous irrigation of the duct with isotonic saline is one of the fundamental stages of a successful sialendoscopic procedure. It allows for an adequate luminal distension for the removal of debris and mucous plugs and for the conservative treatment of strictures. This procedure, which commonly involves the use of a medical syringe, can be laborious, and it is often necessary to interrupt irrigation during surgery due to the high resistance to saline. Setting: Academic university hospital. Method: We propose the use of an irrigation device which consists of a high-pressure syringe barrel, an ergonomic piston handle, and a gauge used to monitor the inflation and deflation of balloon catheters. The system allows for a simple and safe dilation, ensuring good visualization of the salivary duct lumen during sialendoscopy. Conclusions: The irrigation system described can be widely used to perform a diagnostic or interventional sialendoscopy more effectively than with a typical manual irrigation procedure.
Suggested Citation
Giulio Pagliuca & Veronica Clemenzi & Andrea Stolfa & Salvatore Martellucci & Antonio Greco & Marco de Vincentiis & Andrea Gallo, 2022.
"Use of Irrigation Device for Duct Dilatation during Sialendoscopy,"
IJERPH, MDPI, vol. 19(22), pages 1-5, November.
Handle:
RePEc:gam:jijerp:v:19:y:2022:i:22:p:14830-:d:969525
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:19:y:2022:i:22:p:14830-:d:969525. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.