Author
Listed:
- Muhammad Shahzad Chohan
(Department of Biomedical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia)
- Mahesh Attimarad
(Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia)
- Katharigatta Narayanaswamy Venugopala
(Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia
Department of Biotechnology and Food Science, Faculty of Applied Sciences, Durban University of Technology, Durban 4000, South Africa)
- Anroop Balachandran Nair
(Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia)
- Nagaraja Sreeharsha
(Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia
Department of Pharmaceutics, Vidya Siri College of Pharmacy, Off Sarjapura Road, Bangalore 560035, India)
- Efren II Plaza Molina
(Department of Pharmacy Practice, College of Clinical Pharmacy, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia)
- Ramling Bhagavantrao Kotnal
(Department of Pharmaceutical Chemistry, BLDEs College of Pharmacy and Research Centre, Vijayapur 586103, India)
- Sheeba Shafi
(Department of Nursing, College of Applied Medical Sciences, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia)
- Marysheela David
(Department of Nursing, College of Applied Medical Sciences, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia)
- Pottathil Shinu
(Department of Biomedical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia)
- Abdulrahman Ibrahim Altaysan
(Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia)
- Abdulmalek Ahmed Balgoname
(Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf 31982, Al-Ahsa, Saudi Arabia)
Abstract
The development of an environmentally friendly analytical technique for simultaneous measurement of medicines with large concentration differences is difficult yet critical for environmental protection. Hence, in this work, new manipulated UV-spectroscopic methods with high scaling factors were established for concurrent quantification of telmisartan (TEL) and benidipine (BEN) in fixed-dose combinations. Two different methods were developed and established by calculation of peak height at zero crossing point of second derivative and the ratio of first derivative spectra with a scaling factor of 200 and 100, respectively. The absorption difference between the peaks and troughs of the ratio spectra, as well as continuous subtraction from ratio spectra, were established as additional methods. In addition, new procedures were validated using ICH recommendations. The proposed methods’ linearity curves were constructed in the range of 0.5–10 µg mL −1 and 1–30 µg mL −1 for BEN and TEL, respectively, under optimized conditions. Furthermore, both the detection (0.088–0.139 µg mL −1 for BEN and 0.256–0.288 µg mL −1 for TEL) and quantification limits (0.293–0.465 µg mL −1 for BEN and 0.801–0.962 µg mL −1 for TEL) were adequate for quantifying both analytes in the formulation ratios. The accuracy and precision were confirmed by the good recovery percent (98.37%–100.6%), with low percent relative error (0.67%–1.70%) and less than 2 percent relative standard deviation, respectively. The specificity of the methods was proven by accurate and precise outcomes from the standard addition method and analysis of laboratory mixed solutions with large differences in concentrations of both analytes. Finally, the BEN and TEL content of the formulations was determined simultaneously without prior separation using these first ever reported spectroscopic methods. Furthermore, developed UV derivative spectroscopic methods demonstrated high greenness and whiteness when compared to the reported HPLC methods. These findings show that the projected methods were effective, practical, and environmentally acceptable for quality control of BEN and TEL in multicomponent formulations.
Suggested Citation
Muhammad Shahzad Chohan & Mahesh Attimarad & Katharigatta Narayanaswamy Venugopala & Anroop Balachandran Nair & Nagaraja Sreeharsha & Efren II Plaza Molina & Ramling Bhagavantrao Kotnal & Sheeba Shafi, 2022.
"Sensitivity Enhanced Ecofriendly UV Spectrophotometric Methods for Quality Control of Telmisartan and Benidipine Formulations: Comparison of Whiteness and Greenness with HPLC Methods,"
IJERPH, MDPI, vol. 19(12), pages 1-16, June.
Handle:
RePEc:gam:jijerp:v:19:y:2022:i:12:p:7260-:d:838168
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:19:y:2022:i:12:p:7260-:d:838168. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.