Factors That Cause Concerns after Cardioverter Defibrillator Implantation

Author

Listed:
  • Olimpia Karczewska

    (Department of Anaesthesia and Intensive Nursing Care, Faculty of Health Sciences in Katowice, Medical University of Silesia, 40-752 Katowice, Poland
    Department of Gerontology and Geriatric Nursing, Faculty of Health Sciences in Katowice, Medical University of Silesia, 40-635 Katowice, Poland)

  • Agnieszka Młynarska

    (Department of Gerontology and Geriatric Nursing, Faculty of Health Sciences in Katowice, Medical University of Silesia, 40-635 Katowice, Poland)

Abstract

Background and Objectives: The aim of the study was to assess the factors that influence the occurrence of concerns and their intensification after the implantation of a cardioverter defibrillator. Materials and Methods: This was a prospective and observational study including 158 patients. The study was conducted in two stages: stage I before implantable cardioverter defibrillator (ICD) implantation and stage II follow-up visit six months after ICD implantation. Standardized questionnaires were used in both stages. Results: Age and female gender were significantly correlated with the occurrence and intensity of concerns. Patients who had a device implanted for secondary prevention also experienced higher levels of concern. Additionally, a multiple regression model using the stepwise input method was performed. The model was statistically significant and explained 42% of the observed variance in the dependent variable ( p = 0.0001, R 2 = 0.4215). The analysis showed that age ( p = 0.0036), insomnia ( p = 0.0276), anxiety ( p = 0.0000) and negative emotions ( p = 0.0374) were important predictors of the dependent variable and enabled higher levels of the number of concerns to be predicted. Conclusions: There is a relationship between the severity of the concerns related to an implanted ICD and age, gender, anxiety, negative emotions and insomnia. Indications for ICD implantation may be associated with increased concerns about ICD.

Suggested Citation

  • Olimpia Karczewska & Agnieszka Młynarska, 2021. "Factors That Cause Concerns after Cardioverter Defibrillator Implantation," IJERPH, MDPI, vol. 18(11), pages 1-10, June.
  • Handle: RePEc:gam:jijerp:v:18:y:2021:i:11:p:6095-:d:569408
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/18/11/6095/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/18/11/6095/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Łukasz Januszkiewicz & Marcin Grabowski & Michał Mirosław Farkowski & Paweł Życiński & Tomasz Jędrychowski & Mariusz Pytkowski & Julian K. R. Chun & Jose M. Guerra & Giulio Conte & Sérgio Barra & Serg, 2023. "Implantable Cardioverter-Defibrillators in Poland Compared with other European Countries from the Patient’s Perspective: Insights from the EHRA Patient Survey," IJERPH, MDPI, vol. 20(6), pages 1-9, March.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:18:y:2021:i:11:p:6095-:d:569408. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.