IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i9p3223-d354566.html
   My bibliography  Save this article

Biological Monitoring of Metal Ions Released from Hip Prostheses

Author

Listed:
  • Annamaria Nicolli

    (Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, 35128 Padova, Italy)

  • Andrea Trevisan

    (Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, 35128 Padova, Italy)

  • Isabella Bortoletti

    (Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, 35128 Padova, Italy)

  • Assunta Pozzuoli

    (Department of Surgery, Oncology and Gastroenterology, University of Padova, 35128 Padova, Italy)

  • Pietro Ruggieri

    (Department of Surgery, Oncology and Gastroenterology, University of Padova, 35128 Padova, Italy)

  • Andrea Martinelli

    (Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, 35128 Padova, Italy)

  • Alberto Gambalunga

    (Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, 35128 Padova, Italy)

  • Mariella Carrieri

    (Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, 35128 Padova, Italy)

Abstract

The aim of this study was to evaluate the levels of As, Be, Bi, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se, Tl, V, and Zn, by inductively coupled plasma-mass spectrometry (ICP-MS) in the urine of two groups of patients with two different types of metal-on-metal (MoM) total hip prostheses (ASR DePuy ® , group A, 25 patients; total Met-Met System Lima ® , group B, 28 patients). The determination of metals reflected a steady-state release (group A: 9 years after surgery and group B: 6 years after surgery). The results obtained confirmed the increase of Co and Cr urinary levels in both group when compared with the reference values for the general population adopted by the Italian Society of Reference Values (SIVR). In particular, Co and Cr levels exceeded the threshold values in urine, respectively, of 30 μg and 21 µg, adjusted to creatinine based on the threshold in whole blood of 7 μg/L proposed by the Medicines and Healthcare Products Regulatory Agency (MHRA). Regarding the other investigated metals, significantly higher values were found in Group A than in Group B. These differences could be due to the type of hip prosthesis implanted, the longer period of time since the implantation, as well as many other factors such as diet, age, drug consumption, physical activity, or presence of dental fillings. The continuous monitoring over the years of metal concentrations in patients carrying a prosthesis could be useful to better identify the sources of these metals.

Suggested Citation

  • Annamaria Nicolli & Andrea Trevisan & Isabella Bortoletti & Assunta Pozzuoli & Pietro Ruggieri & Andrea Martinelli & Alberto Gambalunga & Mariella Carrieri, 2020. "Biological Monitoring of Metal Ions Released from Hip Prostheses," IJERPH, MDPI, vol. 17(9), pages 1-7, May.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:9:p:3223-:d:354566
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/9/3223/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/9/3223/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:9:p:3223-:d:354566. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.