IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i7p2591-d343902.html
   My bibliography  Save this article

Is Heart Rate a Confounding Factor for Photoplethysmography Markers? A Systematic Review

Author

Listed:
  • Md Rizman Md Lazin Md Lazim

    (Department of Physiology, School of Medical Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia
    Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Jalan Yaacob Latif, Bandar Tun Razak, Cheras 56000, Kuala Lumpur, Malaysia)

  • Amilia Aminuddin

    (Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Jalan Yaacob Latif, Bandar Tun Razak, Cheras 56000, Kuala Lumpur, Malaysia)

  • Kalaivani Chellappan

    (Centre of Advance Electronic & Communication Engineering (PAKET), Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia)

  • Azizah Ugusman

    (Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Jalan Yaacob Latif, Bandar Tun Razak, Cheras 56000, Kuala Lumpur, Malaysia)

  • Adila A Hamid

    (Department of Physiology, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Jalan Yaacob Latif, Bandar Tun Razak, Cheras 56000, Kuala Lumpur, Malaysia)

  • Wan Amir Nizam Wan Ahmad

    (Biomedicine Programme, School of Health Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia)

  • Mohd Shawal Faizal Mohamad

    (Department of Medicine, Faculty of Medicine, Universiti Kebangsaan Malaysia Medical Center, Jalan Yaacob Latif, Bandar Tun Razak, Cheras 56000, Kuala Lumpur, Malaysia)

Abstract

Finger photoplethysmography (PPG) waveform is blood volume change of finger microcirculation that reflects vascular function. Reflection index (RI), stiffness index (SI) and second derivative of photoplethysmogram (SDPPG) are derived from PPG waveforms proposed as cardiovascular disease (CVD) markers. Heart rate (HR) is a known factor that affects vascular function. Individual resting HR variation may affect RI, SI and SDPPG. This review aims to identify studies about the relationship between HR with RI, SI and SDPPG among humans. A literature search was conducted in Medline via the Ebscohost and Scopus databases to find relevant articles published within 11 years. The main inclusion criteria were articles in the English language that discuss the relationship between HR with RI, SI and SDPPG using PPG among humans. The search found 1960 relevant articles but only six articles that met the inclusion criteria. SI and RI showed an association with HR. SDPPG (SDPPG-b/SDPPG-a ratio, SDPPG-d/SDPPG-a ratio, aging index (AGI) and revised aging index (RAGI)) also had an association with HR. Only RI had a considerable association with HR, the association between SI and HR was non-considerable and the association between HR and SDPPG was inconclusive. Further interventional studies should be conducted to investigate this issue, as a variation in resting HR may challenge the validity of PPG-based CVD markers.

Suggested Citation

  • Md Rizman Md Lazin Md Lazim & Amilia Aminuddin & Kalaivani Chellappan & Azizah Ugusman & Adila A Hamid & Wan Amir Nizam Wan Ahmad & Mohd Shawal Faizal Mohamad, 2020. "Is Heart Rate a Confounding Factor for Photoplethysmography Markers? A Systematic Review," IJERPH, MDPI, vol. 17(7), pages 1-12, April.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:7:p:2591-:d:343902
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/7/2591/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/7/2591/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:7:p:2591-:d:343902. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.