IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i3p930-d315732.html
   My bibliography  Save this article

Chloroanisoles and Chlorophenols Explain Mold Odor but Their Impact on the Swedish Population Is Attributed to Dampness and Mold

Author

Listed:
  • Johnny C. Lorentzen

    (Institute of Environmental Medicine, Integrative Toxicology, Karolinska Institutet, 171 77 Stockholm, Sweden)

  • Stephanie A. Juran

    (Institute of Environmental Medicine, Integrative Toxicology, Karolinska Institutet, 171 77 Stockholm, Sweden)

  • Lena Ernstgård

    (Institute of Environmental Medicine, Integrative Toxicology, Karolinska Institutet, 171 77 Stockholm, Sweden)

  • Mats J. Olsson

    (Department of Clinical Neuroscience, Karolinska Institutet, 171 77 Stockholm, Sweden)

  • Gunnar Johanson

    (Institute of Environmental Medicine, Integrative Toxicology, Karolinska Institutet, 171 77 Stockholm, Sweden)

Abstract

We recently reported that mold odor may be explained by chloroanisoles (CAs) formed by microbial biotransformation of chlorophenols (CPs) in legacy wood preservatives. Here we examine psychophysical aspects of CAs and trace their historic origins in buildings. Our exposure of healthy volunteers shows that 2,4,6-triCA is often perceived as unpleasant, characterized as musty or moldy and is detected at 13 ng/m 3 or lower. Similar concentrations are reported in buildings with odor complaints. Scrutiny of written records reveal that new building construction methods were introduced in the 1950s, namely crawlspaces and concrete slabs on the ground. These constructions were prone to dampness and attack from wood decay fungi, prompting chemical companies and authorities to advocate preservatives against rot. Simultaneously, CPs became household chemicals used for example in indoor paints. When large-scale odor problems evolved, the authorities that once approved the preservatives attributed the odor to hidden mold, with no evidence that substantial microbial biomass was necessary for odor formation. Thereby the public remained unaware of problematic exposure to CPs and CAs. We conclude that the introduction of inappropriate designs of house foundations and CP-based preservatives once ignited and still provide impetus for indoor air research on “dampness and mold”.

Suggested Citation

  • Johnny C. Lorentzen & Stephanie A. Juran & Lena Ernstgård & Mats J. Olsson & Gunnar Johanson, 2020. "Chloroanisoles and Chlorophenols Explain Mold Odor but Their Impact on the Swedish Population Is Attributed to Dampness and Mold," IJERPH, MDPI, vol. 17(3), pages 1-20, February.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:3:p:930-:d:315732
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/3/930/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/3/930/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Johnny C. Lorentzen & Gunnar Johanson & Folke Björk & Sofia Stensson, 2022. "Overcrowding and Hazardous Dwelling Condition Characteristics: A Systematic Search and Scoping Review of Relevance for Health," IJERPH, MDPI, vol. 19(23), pages 1-21, November.
    2. Naiela Anwar & Shelley Kirychuk & Chandima P. Karunanayake & Vivian Ramsden & Brooke Thompson & Eric Russell & Kathleen McMullin & Donna Rennie & Jeremy Seeseequasis & Mark Fenton & Sylvia Abonyi & Pu, 2021. "Associations between Housing Factors and Respiratory Symptoms in Two Saskatchewan First Nations Communities," IJERPH, MDPI, vol. 18(7), pages 1-10, April.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:3:p:930-:d:315732. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.