Author
Listed:
- Harsshit Agrawaal
(Department of Chemistry & Biochemistry, Texas Tech University, Box 41061, Lubbock, TX 79409-1061, USA)
- Courtney Jones
(Department of Chemistry & Biochemistry, Texas Tech University, Box 41061, Lubbock, TX 79409-1061, USA)
- J.E. Thompson
(Department of Chemistry & Biochemistry, Texas Tech University, Box 41061, Lubbock, TX 79409-1061, USA)
Abstract
Low-cost, portable particle sensors (n = 3) were designed, constructed, and used to monitor human exposure to particle pollution at various locations and times in Lubbock, TX. The air sensors consisted of a Sharp GP2Y1010AU0F dust sensor interfaced to an Arduino Uno R3, and a FONA808 3G communications module. The Arduino Uno was used to receive the signal from calibrated dust sensors to provide a concentration (µg/m 3 ) of suspended particulate matter and coordinate wireless transmission of data via the 3G cellular network. Prior to use for monitoring, dust sensors were calibrated against a reference aerosol monitor (RAM-1) operating independently. Sodium chloride particles were generated inside of a 3.6 m 3 mixing chamber while the RAM-1 and each dust sensor recorded signals and calibration was achieved for each dust sensor independently of others by direct comparison with the RAM-1 reading. In an effort to improve the quality of the data stream, the effect of averaging replicate individual pulses of the Sharp sensor when analyzing zero air has been studied. Averaging data points exponentially reduces standard deviation for all sensors with n < 2000 averages but averaging produced diminishing returns after approx. 2000 averages. The sensors exhibited standard deviations for replicate measurements of 3–6 µg/m 3 and corresponding 3σ detection limits of 9–18 µg/m 3 when 2000 pulses of the dust sensor LED were averaged over an approx. 2 min data collection/transmission cycle. To demonstrate portable monitoring, concentration values from the dust sensors were sent wirelessly in real time to a ThingSpeak channel, while tracking the sensor’s latitude and longitude using an on-board Global Positioning System (GPS) sensor. Outdoor and indoor air quality measurements were made at different places and times while human volunteers carried sensors. The measurements indicated walking by restaurants and cooking at home increased the exposure to particulate matter. The construction of the dust sensors and data collected from this research enhance the current research by describing an open-source concept and providing initial measurements. In principle, sensors can be massively multiplexed and used to generate real-time maps of particulate matter around a given location.
Suggested Citation
Harsshit Agrawaal & Courtney Jones & J.E. Thompson, 2020.
"Personal Exposure Estimates via Portable and Wireless Sensing and Reporting of Particulate Pollution,"
IJERPH, MDPI, vol. 17(3), pages 1-15, January.
Handle:
RePEc:gam:jijerp:v:17:y:2020:i:3:p:843-:d:314091
Download full text from publisher
Citations
Citations are extracted by the
CitEc Project, subscribe to its
RSS feed for this item.
Cited by:
- Nicoletta Lotrecchiano & Vincenzo Capozzi & Daniele Sofia, 2021.
"An Innovative Approach to Determining the Contribution of Saharan Dust to Pollution,"
IJERPH, MDPI, vol. 18(11), pages 1-17, June.
- Nuno Canha & Evangelia Diapouli & Susana Marta Almeida, 2021.
"Integrated Human Exposure to Air Pollution,"
IJERPH, MDPI, vol. 18(5), pages 1-6, February.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:3:p:843-:d:314091. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.