Author
Listed:
- Ana Sofia Vinhas
(Department of Periodontology, Instituto Universitário de Ciências da Saúde, 4585-116 Gandra, Portugal)
- Carlos Aroso
(Department of Prosthodontics, Instituto Universitário de Ciências da Saúde, 4585-116 Gandra, Portugal)
- Filomena Salazar
(Department of Periodontology, Instituto Universitário de Ciências da Saúde, 4585-116 Gandra, Portugal)
- Paula López-Jarana
(Department of Periodontology, Instituto Universitário de Ciências da Saúde, 4585-116 Gandra, Portugal)
- José Vicente Ríos-Santos
(Department of Periodontology, School of Dentistry, Universidad de Sevilla, C/Avicena S/N, 41009 Sevilla, Spain)
- Mariano Herrero-Climent
(Porto Dental Institute, 4150-518 Porto, Portugal)
Abstract
Introduction: Different implant–abutment connections have been developed to reduce mechanical and biological failure. The most frequent complications are loss of preload, screw loosening, abutment or implant fracture, deformations at the different interfaces, and bacterial microleakage. Aim: To review the evidence indicating whether the implant–abutment connection type is significant regarding the following issues: (1) maintenance of the preload in static and dynamic in vitro studies; (2) assessment of possible deformations at the implant–abutment interfaces, after repeated application of the tightening torque; (3) evaluation of the sealing capability of different implant connections against microleakage. Materials and Methods: In June 2020, an electronic literature search was performed in Medline, EBSCO host, and PubMed databases. The search was focused on the ability of different implant connections to maintain preload, resist deformation after tightening and retightening, and prevent microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full-text reading. Results: The literature search conducted for this review initially resulted in 68 articles, among which 19 articles and 1 systematic review fulfilled the criteria for inclusion. The studies were divided according to the three proposed objectives, with some studies falling into more than one category (maintenance of preload, surface abutment–implant deformation, and resistance to microleakage). Conclusions: Conical abutment appears to result in fewer mechanical complications, such as screw loosening or fractures, and higher torque preservation. After SEM evaluation, damage was observed in the threads of the abutment screws, before and after loading in internal and external connections. Internal hexagon implants and predominantly internal conical (Morse taper) implants showed less microleakage in dynamic loading conditions. We suggest further studies to guarantee excellence in methodological quality.
Suggested Citation
Ana Sofia Vinhas & Carlos Aroso & Filomena Salazar & Paula López-Jarana & José Vicente Ríos-Santos & Mariano Herrero-Climent, 2020.
"Review of the Mechanical Behavior of Different Implant–Abutment Connections,"
IJERPH, MDPI, vol. 17(22), pages 1-20, November.
Handle:
RePEc:gam:jijerp:v:17:y:2020:i:22:p:8685-:d:449534
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:22:p:8685-:d:449534. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.