IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i19p7287-d424156.html
   My bibliography  Save this article

Effects of Inhaled Corticosteroids and Particle Size on Risk of Obstructive Sleep Apnea: A Large Retrospective Cohort Study

Author

Listed:
  • Maria Paula Henao

    (Division of Allergy, Asthma, and Immunology, Penn State Hershey Medical Center, Hershey, PA 17033, USA)

  • Jennifer L. Kraschnewski

    (Department of Medicine, Penn State Hershey Medical Center, Hershey, PA 17033, USA)

  • Matthew D. Bolton

    (Bioinformatics and Enterprise Information Management, Penn State Hershey Medical Center, Hershey, PA 17033, USA)

  • Faoud Ishmael

    (Division of Allergy, Asthma, and Immunology, Penn State Hershey Medical Center, Hershey, PA 17033, USA)

  • Timothy Craig

    (Division of Allergy, Asthma, and Immunology, Penn State Hershey Medical Center, Hershey, PA 17033, USA)

Abstract

Background: Inhaled corticosteroids (ICS) produce local effects on upper airway dilators that could increase the risk of developing obstructive sleep apnea (OSA). Given that the particle size of ICS changes their distribution, the particle size of ICS may impact the risk of developing OSA. Objectives: In this large retrospective study, we explore the relationship of ICS use and OSA in patients with asthma. In addition, we seek to determine if this relationship is affected by the particle size of ICS. Methods : Using electronic health records, we established a cohort of 29,816 asthmatics aged 12 and older with a diagnosis of asthma documented by ICD-9 or ICD-10 codes between January 2011 and August 2016. We performed analyses of variance and multivariate logistic regression analysis to determine the effects ICS on the diagnosis of OSA with sub-analysis by particle size of ICS. Results: Uncontrolled asthmatics showed increased odds of receiving a diagnosis of OSA whether when looking at ACT scores (adjusted odds ratio (aOR) 1.60, 95% CI 1.32–1.94) or PFT results (aOR 1.45, 95% CI 1.19–1.77). Users of ICS also had increased odds of OSA independent of asthma control (aOR 1.58, 95% CI 1.47–1.70). Notably, users of extra-fine particle ICS did not have significantly increased odds of having OSA compared to non-users of ICS (aOR 1.11, 95% CI 0.78–1.58). Conclusions : Use of ICS appears to be an independent risk factor for OSA. Notably, extra-fine particle size ICS do not appear to be associated with an increased risk of OSA.

Suggested Citation

  • Maria Paula Henao & Jennifer L. Kraschnewski & Matthew D. Bolton & Faoud Ishmael & Timothy Craig, 2020. "Effects of Inhaled Corticosteroids and Particle Size on Risk of Obstructive Sleep Apnea: A Large Retrospective Cohort Study," IJERPH, MDPI, vol. 17(19), pages 1-9, October.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:19:p:7287-:d:424156
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/19/7287/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/19/7287/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:19:p:7287-:d:424156. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.