Author
Listed:
- Eva Pertile
(Faculty of Mining and Geology, Department of Environmental Engineering, VSB—Technical University of Ostrava, 708 00 Ostrava, Czech Republic)
- Vojtech Vaclavik
(Faculty of Mining and Geology, Department of Environmental Engineering, VSB—Technical University of Ostrava, 708 00 Ostrava, Czech Republic)
- Tomas Dvorsky
(Faculty of Mining and Geology, Department of Environmental Engineering, VSB—Technical University of Ostrava, 708 00 Ostrava, Czech Republic)
- Silvie Heviankova
(Faculty of Mining and Geology, Department of Environmental Engineering, VSB—Technical University of Ostrava, 708 00 Ostrava, Czech Republic)
Abstract
This article deals with the possibility of using a biosorbent in the form of a mixture of cones from coniferous trees to remove the residual concentration of hazardous metals contained in hazardous waste, which is disposed of in a neutralization station. The efficiency of the tested biosorbent in removing Ni, Zn, Cu, and Fe was monitored here. Laboratory research was carried out before the actual testing of the biosorbent directly in the operation of the neutralization station. With regard to the planned use of the biosorbent in the operational test, the laboratory experiments were performed in a batch mode and for the most problematic metals (Ni and Zn). The laboratory tests with real wastewater have shown that the biosorbent can be used to remove hazardous metals. Under the given conditions, 96% of Ni and 19% of Zn were removed after 20 min when using NaOH activated biosorbent with the concentration of 0.1 mol L −1 . The inactivated biosorbent removed 93% of Ni and 31% of Zn. The tested biosorbent was also successful during the operational tests. The inactivated biosorbent was applied due to the financial costs. It was used for the pre-treatment of hazardous waste in a preparation tank, where a significant reduction in the concentration of hazardous metals occurred, but the values of Ni, Cu, and Zn still failed to meet the emission limits. After 72 h, we measured 10 mg L −1 from the original 4,056 mg L −1 of Ni, 1 mg L −1 from the original 2,252 mg L −1 of Cu, 1 mg L −1 from the original 4,020 mg L –1 of Zn, and 7 mg L −1 from the original 1,853 mg L −1 of Fe. However, even after neutralization, the treated water did not meet the emission limits for discharging into the sewer system. The biosorbent was, therefore, used in the filtration unit as well, which was placed in front of the Parshall flume. After passing through the filtration unit, the concentrations of all the monitored parameters were reduced to a minimum, and the values met the prescribed emission limits. The biosorbent was further used to thicken the residual sludge in the waste pre-treatment tank, which contributed to a significant reduction in the overall cost of disposing of residual hazardous waste. This waste was converted from liquid to solid-state.
Suggested Citation
Eva Pertile & Vojtech Vaclavik & Tomas Dvorsky & Silvie Heviankova, 2020.
"The Removal of Residual Concentration of Hazardous Metals in Wastewater from a Neutralization Station Using Biosorbent—A Case Study Company Gutra, Czech Republic,"
IJERPH, MDPI, vol. 17(19), pages 1-14, October.
Handle:
RePEc:gam:jijerp:v:17:y:2020:i:19:p:7225-:d:423097
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:19:p:7225-:d:423097. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.