IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i16p5651-d394956.html
   My bibliography  Save this article

Absolute Accelerometer-Based Intensity Prescription Compared to Physiological Variables in Pregnant and Nonpregnant Women

Author

Listed:
  • Philipp Birnbaumer

    (Institute of Human Movement Science, Sport and Health, University of Graz, 8010 Graz, Austria)

  • Pavel Dietz

    (Institute of Occupational, Social and Environmental Medicine, University Medical Center of the University of Mainz, 55131 Mainz, Germany)

  • Estelle Dorothy Watson

    (School of Therapeutic Sciences, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg 2000, South Africa)

  • Gudani Mukoma

    (School of Therapeutic Sciences, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg 2000, South Africa
    South African MRC/Wits Developmental Pathways for Health Research Unit, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg 2000, South Africa)

  • Alexander Müller

    (Institute of Human Movement Science, Sport and Health, University of Graz, 8010 Graz, Austria)

  • Matteo Christian Sattler

    (Institute of Human Movement Science, Sport and Health, University of Graz, 8010 Graz, Austria)

  • Johannes Jaunig

    (Institute of Human Movement Science, Sport and Health, University of Graz, 8010 Graz, Austria)

  • Mireille Nicoline Maria van Poppel

    (Institute of Human Movement Science, Sport and Health, University of Graz, 8010 Graz, Austria)

  • Peter Hofmann

    (Institute of Human Movement Science, Sport and Health, University of Graz, 8010 Graz, Austria)

Abstract

Estimation of the intensity of physical activity (PA) based on absolute accelerometer cut points (Cp) likely over- or underestimates intensity for a specific individual. The purpose of this study was to investigate the relationship between absolute moderate intensity Cp and the first ventilatory threshold (VT 1 ). A group of 24 pregnant and 15 nonpregnant women who performed a submaximal incremental walking test with measures of ventilatory parameters and accelerations from three different accelerometers on the wrist (ActiGraph wGT3X-BT, GENEActiv, Axivity AX3) and one on the hip (Actigraph wGT3X-BT) were analyzed. Cp were determined corresponding to 3 metabolic equivalents of task (MET), using the conventional MET definition (Cp 3.5 ) (3.5 mL/kg×min) and individual resting metabolic rate (Cp ind ). The ventilatory equivalent (VE/VO 2 ) was used to determine VT 1 . Accelerations at VT 1 were significantly higher ( p < 0.01) compared to Cp 3.5 and Cp ind in both groups. Cp 3.5 and Cp ind were significantly different in nonpregnant ( p < 0.01) but not in pregnant women. Walking speed at VT 1 (5.7 ± 0.5/6.2 ± 0.8 km/h) was significantly lower ( p < 0.01) in pregnant compared to nonpregnant women and correspondent to 3.8 ± 0.7/4.9 ± 1.4 conventional METs. Intensity at absolute Cp was lower compared to the intensity at VT 1 independent of the device or placement in pregnant and nonpregnant women. Therefore, we recommend individually tailored cut points such as the VT 1 to better assess the effect of the intensity of PA.

Suggested Citation

  • Philipp Birnbaumer & Pavel Dietz & Estelle Dorothy Watson & Gudani Mukoma & Alexander Müller & Matteo Christian Sattler & Johannes Jaunig & Mireille Nicoline Maria van Poppel & Peter Hofmann, 2020. "Absolute Accelerometer-Based Intensity Prescription Compared to Physiological Variables in Pregnant and Nonpregnant Women," IJERPH, MDPI, vol. 17(16), pages 1-10, August.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:16:p:5651-:d:394956
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/16/5651/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/16/5651/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Marieke De Craemer & Vera Verbestel, 2021. "Comparison of Outcomes Derived from the ActiGraph GT3X+ and the Axivity AX3 Accelerometer to Objectively Measure 24-Hour Movement Behaviors in Adults: A Cross-Sectional Study," IJERPH, MDPI, vol. 19(1), pages 1-8, December.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:16:p:5651-:d:394956. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.