IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i15p5561-d393222.html
   My bibliography  Save this article

Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods

Author

Listed:
  • Hyungyu Park

    (Department of Architecture, Graduated School, Kookmin University, Seoul 02707, Korea)

  • Seonghyun Park

    (Department of Industry-Academic Cooperation Foundation, Kookmin University, Seoul 02707, Korea)

  • Janghoo Seo

    (School of Architecture, Kookmin University, Seoul 02707, Korea)

Abstract

Fine particulate matter entering the body through breathing cause serious damage to humans. In South Korea, filter-type air purifiers are used to eliminate indoor fine particulate matter, and there has been a broad range of studies on the spread of fine particulate matter and air purifiers. However, earlier studies have not evaluated an operating method of air purifiers considering the inflow of fine particulate matter into the body or reduction performance of the concentration of fine particulate matter. There is a limit to controlling the concentration of fine particulate matter of the overall space where an air purifier is fixed in one spot as the source of indoor fine particulate matter is varied. Accordingly, this study analyzed changes in the concentration of indoor fine particulate matter through an experiment according to the discharging method and location of a fixed air purifier considering the inflow route of fine particulate matter into the body and their harmfulness. The study evaluated the purifiers’ performance in reducing the concentration of fine particulate matter in the occupants’ breathing zone according to the operation method in which a movable air purifier responds to the movement of occupants. The results showed the concentration of fine particulate matter around the breathing zone of the occupants had decreased by about 51 μg/m 3 compared to the surrounding concentration in terms of the operating method in which an air purifier tracks occupants in real-time, and a decrease of about 68 μg/m 3 in terms of the operating method in which an air purifier controls the zone. On the other hand, a real-time occupant tracking method may face a threshold due to the moving path of an air purifier and changes in the number of occupants. A zone controlling method is deemed suitable as an operating method of a movable air purifier to reduce the concentration of fine particulate matter in the breathing zone of occupants.

Suggested Citation

  • Hyungyu Park & Seonghyun Park & Janghoo Seo, 2020. "Evaluation on Air Purifier’s Performance in Reducing the Concentration of Fine Particulate Matter for Occupants according to its Operation Methods," IJERPH, MDPI, vol. 17(15), pages 1-14, August.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:15:p:5561-:d:393222
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/15/5561/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/15/5561/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Seonghyun Park & Janghoo Seo & Sunwoo Lee, 2020. "Distribution Characteristics of Indoor PM 2.5 Concentration Based on the Water Type and Humidification Method," IJERPH, MDPI, vol. 17(22), pages 1-15, November.
    2. Nuno Canha & Evangelia Diapouli & Susana Marta Almeida, 2021. "Integrated Human Exposure to Air Pollution," IJERPH, MDPI, vol. 18(5), pages 1-6, February.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:15:p:5561-:d:393222. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.