IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i13p4656-d377464.html
   My bibliography  Save this article

Colorimetric Quantification Methods for Peracetic Acid together with Hydrogen Peroxide for Water Disinfection Process Control

Author

Listed:
  • Ravi Kumar Chhetri

    (Department of Environmental Engineering, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark)

  • Kamilla Marie Speht Kaarsholm

    (Department of Environmental Engineering, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark)

  • Henrik Rasmus Andersen

    (Department of Environmental Engineering, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark)

Abstract

Peracetic acid (PAA) water solutions is applied for disinfection of industry systems, food products and non-potable water. Commercially available peracetic acid is always supplied mixed with hydrogen peroxide (H 2 O 2 ). H 2 O 2 degrade slower than the peracetic acid which creates a need to quantify both peroxides separately to gauge the disinfection power of the solution and the residuals. Two combinations of colorimetric reactions are presented that allows simultaneous quantification at the mg·L −1 level used in disinfection liquids and water disinfection. The first dichromic reaction use titanium oxide oxalate (TiO-Ox) which only react with H 2 O 2 followed by addition of N,N-diethyl-p-phenylenediamine with iodide (DPD/I − ) and the concentrations are read by simultaneously measuring the absorbance at 400 and 515 nm. Limit of quantification (LOQ) and maximal concentration determined was 4.6 µg·L −1 and 2.5 mg·L −1 for PAA and 9.1 µg·L −1 and 5 mg·L −1 for H 2 O 2 . The two color reactions didn’t interfere with each other when the reagent addition was consecutive. Another combination of colorimetric reaction also used where TiO-Ox was used to first measure H 2 O 2 at 400 nm, before addition of 2,2’-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid (ABTS)) and reading the absorbance at 405 nm. ABTS changes the absorbance at 405 nm necessitating the two measurements be done separately. LOQ and maximal concentration determined using ABTS colorimetric assay was 42.5 µg·L −1 and 30 mg·L −1 for PAA and for titanium oxide oxalate colorimetric assay was 12.7 µg·L −1 and 75 mg·L −1 for H 2 O 2 . Both methods tested satisfactory in typical water samples (Tap, sea, lake, and biological treated sewage) spiked with peracetic acid and H 2 O 2 , separately.

Suggested Citation

  • Ravi Kumar Chhetri & Kamilla Marie Speht Kaarsholm & Henrik Rasmus Andersen, 2020. "Colorimetric Quantification Methods for Peracetic Acid together with Hydrogen Peroxide for Water Disinfection Process Control," IJERPH, MDPI, vol. 17(13), pages 1-11, June.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:13:p:4656-:d:377464
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/13/4656/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/13/4656/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Ravi Kumar Chhetri & Silvia Di Gaetano & Andrea Turolla & Manuela Antonelli & Henrik Rasmus Andersen, 2020. "Ecotoxicity Evaluation of Pure Peracetic Acid (PAA) after Eliminating Hydrogen Peroxide from Commercial PAA," IJERPH, MDPI, vol. 17(14), pages 1-9, July.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:13:p:4656-:d:377464. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.