Is It Possible to Monitor Implant Stability on a Prosthetic Abutment? An In Vitro Resonance Frequency Analysis

Author

Listed:
  • Paula López-Jarana

    (Private Practice, Porto Dental Institute, Av. de Montevideu 810, 4150-518 Porto, Portugal)

  • Carmen María Díaz-Castro

    (Master’s Program of Periodontology and Implant Dentistry, University of Seville, Calle San Fernando, 4, 41004 Sevilla, Spain)

  • Artur Falcão

    (Private Practice, Porto Dental Institute, Av. de Montevideu 810, 4150-518 Porto, Portugal)

  • Blanca Ríos-Carrasco

    (Master’s Program of Periodontology and Implant Dentistry, University of Seville, Calle San Fernando, 4, 41004 Sevilla, Spain)

  • Ana Fernandez-Palacín

    (Department of Social and Health Sciences, University of Seville, Calle San Fernando, 4, 41004 Sevilla, Spain)

  • José-Vicente Ríos-Santos

    (Department of Periodontics and Implant Dentistry, Dental School University of Seville, C/Avicena S/N, 41009 Sevilla, Spain)

  • Mariano Herrero-Climent

    (Porto Dental Institute, Av. de Montevideu 810, 4150-518 Porto, Portugal)

Abstract

In order to apply the “one-abutment–one-time” concept, we evaluated the possibility of measuring resonance frequency analysis (RFA) on the abutment. This trial aimed to compare the Implant Stability Quotient (ISQ) values obtained by the Penguin RFA when screwing the transducer onto the implant or onto abutments with different heights and angulations. Eighty implants (VEGA ® , Klockner Implant System, SOADCO, Les Escaldes, Andorra) were inserted into fresh bovine ribs. The groups were composed of 20 implants, 12 mm in length, with two diameters (3.5 and 4 mm). Five different abutments for screwed retained restorations (Permanent ® ) were placed as follows: straight with 1, 2, and 3 mm heights, and angulated at 18° with 2 and 3 mm heights. The mean value of the ISQ measured directly on the implant was 75.72 ± 4.37. The mean value of the ISQ registered over straight abutments was 79.5 ± 8.50, 76.12 ± 6.63, and 71.42 ± 6.86 for 1, 2, and 3 mm height abutments. The mean ISQ over angled abutments of 2 and 3 mm heights were 68.74 ± 4.68 and 64.51 ± 4.53 respectively. The present study demonstrates that, when the ISQ is registered over the straight abutments of 2 and 3 mm heights, the values decrease, and values are lower for angled, 3 mm height abutments.

Suggested Citation

  • Paula López-Jarana & Carmen María Díaz-Castro & Artur Falcão & Blanca Ríos-Carrasco & Ana Fernandez-Palacín & José-Vicente Ríos-Santos & Mariano Herrero-Climent, 2020. "Is It Possible to Monitor Implant Stability on a Prosthetic Abutment? An In Vitro Resonance Frequency Analysis," IJERPH, MDPI, vol. 17(11), pages 1-14, June.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:11:p:4073-:d:368508
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/11/4073/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/11/4073/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:11:p:4073-:d:368508. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.