IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v16y2019i20p3934-d277050.html
   My bibliography  Save this article

Influence of Intensity RAMP Incremental Test on Peak Power, Post-Exercise Blood Lactate, and Heart Rate Recovery in Males: Cross-Over Study

Author

Listed:
  • Kamil Michalik

    (Department of Physiology and Biochemistry, Faculty of Physical Education, University School of Physical Education in Wroclaw, 35 Paderewskiego Street, 51-612 Wroclaw, Poland)

  • Kuba Korta

    (Department of Physiology and Biochemistry, Faculty of Physical Education, University School of Physical Education in Wroclaw, 35 Paderewskiego Street, 51-612 Wroclaw, Poland)

  • Natalia Danek

    (Department of Physiology and Biochemistry, Faculty of Physical Education, University School of Physical Education in Wroclaw, 35 Paderewskiego Street, 51-612 Wroclaw, Poland)

  • Marcin Smolarek

    (Department of Physiology and Biochemistry, Faculty of Physical Education, University School of Physical Education in Wroclaw, 35 Paderewskiego Street, 51-612 Wroclaw, Poland)

  • Marek Zatoń

    (Department of Physiology and Biochemistry, Faculty of Physical Education, University School of Physical Education in Wroclaw, 35 Paderewskiego Street, 51-612 Wroclaw, Poland)

Abstract

Background: The linearly increased loading (RAMP) incremental test is a method commonly used to evaluate physical performance in a laboratory, but the best-designed protocol remains unknown. The aim of this study was to compare the selected variables used in training control resulting from the two different intensities of RAMP incremental tests. Methods: Twenty healthy and physically active men took part in this experiment. The tests included two visits to a laboratory, during which anthropometric measurements, incremental test on a cycle ergometer, and examinations of heart rate and blood lactate concentration were made. The cross-over study design method was used. The subjects underwent a randomly selected RAMP test with incremental load: 0.278 W·s −1 or 0.556 W·s −1 . They performed the second test a week later. Results: Peak power output was significantly higher by 51.69 W ( p < 0.001; t = 13.10; ES = 1.13) in the 0.556 W·s −1 group. Total work done was significantly higher in the 0.278 W·s −1 group by 71.93 kJ ( p < 0.001; t = 12.55; ES = 1.57). Maximal heart rate was significantly higher in the 0.278 W·s −1 group by 3.30 bpm ( p < 0.01; t = 3.72; ES = 0.48). There were no statistically significant differences in heart rate recovery and peak blood lactate. Conclusions: We recommend use of the 0.556 W·s −1 RAMP protocol because it is of shorter duration compared with 0.278 W·s −1 and as such practically easier and of less effort for subjects.

Suggested Citation

  • Kamil Michalik & Kuba Korta & Natalia Danek & Marcin Smolarek & Marek Zatoń, 2019. "Influence of Intensity RAMP Incremental Test on Peak Power, Post-Exercise Blood Lactate, and Heart Rate Recovery in Males: Cross-Over Study," IJERPH, MDPI, vol. 16(20), pages 1-8, October.
  • Handle: RePEc:gam:jijerp:v:16:y:2019:i:20:p:3934-:d:277050
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/16/20/3934/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/16/20/3934/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:16:y:2019:i:20:p:3934-:d:277050. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.