Author
Listed:
- Christian Apelmann
(BG Klinikum Hamburg, Bergedorfer Str. 10, 21033 Hamburg, Germany)
- Birgitt Kowald
(BG Klinikum Hamburg, Bergedorfer Str. 10, 21033 Hamburg, Germany)
- Nils Weinrich
(BG Klinikum Hamburg, Bergedorfer Str. 10, 21033 Hamburg, Germany)
- Jens Dischinger
(Northern German Seminar for Radiation Protection gGmbH at the Christian-Albrechts-University Kiel, 24098 Kiel, Germany)
- Albert Nienhaus
(Competence Centre for Epidemiology and Health Services Research for Healthcare Professionals (CVcare), University Medical Centre Hamburg-Eppendorf (UKE), 20246 Hamburg, Germany)
- Klaus Seide
(BG Klinikum Hamburg, Bergedorfer Str. 10, 21033 Hamburg, Germany)
- Heiko Martens
(B.A.D. Gesundheitsvorsorge und Sicherheitstechnik GmbH, 21033 Hamburg, Germany)
- Christian Jürgens
(BG Klinikum Hamburg, Bergedorfer Str. 10, 21033 Hamburg, Germany)
Abstract
Background : Due to the drastic reduction of the eye lens dose limit from 150 mSv per year to 20 mSv per year since 2018, the prospective investigation of the estimated dose of the eye lens by radiological imaging procedures at the surgical site during trauma surgery in the daily work process was carried out. This was also necessary because, as experience shows, with changes in surgical techniques, there are also changes in the use of radiological procedures, and thus an up-to-date inventory can provide valuable information for the assessment of occupationally induced radiation exposure of surgical personnel under the current conditions. Methods : The eye lens radiation exposure was measured over three months for five trauma surgeons, four hand surgeons and four surgical assistants with personalized LPS-TLD-TD 07 partial body dosimeters Hp (0.07). A reference dosimeter was deposited at the surgery changing room. The dosimeters were sent to the LPS (Landesanstalt für Personendosimetrie und Strahlenschutzausbildung) measuring institute (National Institute for Personal Dosimetry and Radiation Protection Training, Berlin) for evaluation after 3 months. The duration of the operation, occupation (assistant, surgeon, etc.), type of surgery (procedure, diagnosis), designation of the X-ray unit, total duration of radiation exposure per operation and dose area product per operation were recorded. Results : Both the evaluation of the dosimeters by the trauma surgeons and the evaluation of the dosimeters by the hand surgeons and the surgical assistants revealed no significant radiation exposure of the eye lens in comparison to the respective measured reference dosimeters. Conclusions : Despite the drastic reduction of the eye lens dose limit from 150 mSv per year to 20 mSv per year, the limit for orthopedic, trauma and hand surgery operations is well below the limit in this setting.
Suggested Citation
Christian Apelmann & Birgitt Kowald & Nils Weinrich & Jens Dischinger & Albert Nienhaus & Klaus Seide & Heiko Martens & Christian Jürgens, 2019.
"Radiation Dose to the Eye Lens through Radiological Imaging Procedures at the Surgical Workplace during Trauma Surgery,"
IJERPH, MDPI, vol. 16(20), pages 1-13, October.
Handle:
RePEc:gam:jijerp:v:16:y:2019:i:20:p:3850-:d:275547
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:16:y:2019:i:20:p:3850-:d:275547. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.