IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v16y2019i15p2742-d253595.html
   My bibliography  Save this article

Corneal Buckling during Applanation and Its Effect on the Air Pressure Curve in Ocular Response Analyzer

Author

Listed:
  • Agnieszka Jóźwik

    (Department of Optics and Photonics, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland)

  • Henryk Kasprzak

    (Department of Optics and Photonics, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland)

  • Agata Kozakiewicz

    (Department of Optics and Photonics, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland)

Abstract

The paper presents, for the first time, corneal buckling, during the air puff applanation, recorded with use of Ocular Response Analyzer (ORA), when the cornea is deeper deformed after its applanation. Precise numerical analysis of the air pressure curve from the raw data, distinct local disturbances of the curve, which appear almost exactly at the time of the first and the second applanations. Thirty measurements taken on six eyes show clear dependencies between times of both applanations and appearances of local wave disturbances on the air pressure curve as well as between the amplitude of pressure wave disturbances and the respective height of applanation curve. These findings can be interpreted as a result of very fast corneal buckling, that produces the air pressure wave, propagating from the cornea towards the device. The quantitative dependencies measured and described in this study, enable to characterize the individual buckling during respective applanations. Due to these individual characterizations and dependencies it is possible to understand and describe better the ultrafast corneal applanation process. Such phenomena could likely be employed to increase the accuracy of measured parameters by ORA or for identifying new types of biomechanical properties of the cornea.

Suggested Citation

  • Agnieszka Jóźwik & Henryk Kasprzak & Agata Kozakiewicz, 2019. "Corneal Buckling during Applanation and Its Effect on the Air Pressure Curve in Ocular Response Analyzer," IJERPH, MDPI, vol. 16(15), pages 1-10, July.
  • Handle: RePEc:gam:jijerp:v:16:y:2019:i:15:p:2742-:d:253595
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/16/15/2742/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/16/15/2742/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:16:y:2019:i:15:p:2742-:d:253595. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.