IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v16y2019i13p2388-d245953.html
   My bibliography  Save this article

A Clinical Trial of the Effect of a Blood Leakage Detection Device for Patients during Hemodialysis

Author

Listed:
  • Yang-Kun Ou

    (Department of Creative Product Design, Southern Taiwan University of Science and Technology, No. 1, Nan-Tai Street, Yungkang District, Tainan 71005, Taiwan)

  • Ming-Jui Wu

    (Department of Internal Medicine, Kaohsiung Veterans General Hospital Tainan Branch, No. 427, Fuxing Road, Yongkang District, Tainan 71051, Taiwan
    Department of Electrical Engineering, Southern Taiwan University of Science and Technology, No. 1, Nan-Tai Street, Yungkang District, Tainan 71005, Taiwan)

  • Wei-Siang Ciou

    (Department of Electrical Engineering, Southern Taiwan University of Science and Technology, No. 1, Nan-Tai Street, Yungkang District, Tainan 71005, Taiwan)

  • Yi-Chun Du

    (Department of Electrical Engineering, Southern Taiwan University of Science and Technology, No. 1, Nan-Tai Street, Yungkang District, Tainan 71005, Taiwan)

Abstract

In hemodialysis, vascular access is usually achieved through an arteriovenous fistula, and a dislodged needle can cause varying degrees of injury to patients. In severe cases, the loss of blood can prove to be fatal. This study proposed a blood leakage detection device for patients during hemodialysis (HD). First, the device was tested on a phantom arm, and later in a clinical test on patients receiving HD. The thoughts of the patients and the nursing staff involved were surveyed before and after the introduction of the device. Analysis of the results indicated that the device achieved 100% and 98.9% accuracy rates on the phantom arm test and clinical test, respectively. The results suggested that patients believed the device could reduce their mental anxiety, and the nursing staff considered the device reliable and that it would enhance the quality of care. The proposed detection device can be extended to similar applications for preventing catheter dislodgement, and to improve patient safety and reduce the stress of clinical nursing staff.

Suggested Citation

  • Yang-Kun Ou & Ming-Jui Wu & Wei-Siang Ciou & Yi-Chun Du, 2019. "A Clinical Trial of the Effect of a Blood Leakage Detection Device for Patients during Hemodialysis," IJERPH, MDPI, vol. 16(13), pages 1-10, July.
  • Handle: RePEc:gam:jijerp:v:16:y:2019:i:13:p:2388-:d:245953
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/16/13/2388/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/16/13/2388/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:16:y:2019:i:13:p:2388-:d:245953. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.