Author
Listed:
- Francesco Guido Mangano
(Lecturer, Department of Medicine and Surgery, University of Insubria, 21100 Varese, Italy
Professor, Department of Prevention and Communal Dentistry, I.M. Sechenov First Moscow State Medical University, 119992 Moscow, Russia)
- Uli Hauschild
(Private Practice, 18038 San Remo, Italy)
- Oleg Admakin
(Professor, Department of Prevention and Communal Dentistry, I.M. Sechenov First Moscow State Medical University, 119992 Moscow, Russia)
Abstract
Background: Guided implant surgery appears to have several benefits, such as the possibility of inserting flapless implants in a prosthetically driven manner, avoiding dangerous anatomical structures. However, to date, only a few surgeons routinely use guided surgery in partially edentulous patients. Aim: To present the results obtained with tooth-supported surgical templates characterized by an innovative open design with selective support, and manufactured via a full in-office procedure with a low-cost desktop 3D printer. Methods: Over a two-year period (2016–2018), all partially edentulous patients with one to three missing teeth (in maxilla and/or mandible), referred to a private dental practice for restoration with dental implants, were considered for inclusion in this prospective clinical study. An intraoral scanner (CS 3600 ® , Carestream Dental) and cone beam computed tomography (CS 9300 ® , Carestream Dental) were used to acquire the 3D information on the patients. Guided surgery software (SMOP ® , Swissmeda) was used to plan the surgeries and to design open, selective, tooth-supported templates that were fabricated with a stereolithographic (SLA) desktop 3D printer (XFAB2000 ® , DWS). Guided implant surgeries were performed and patients were followed for a period of one year. The study outcomes were fit and stability of surgical templates, duration (time) of surgery, intra and post-operative complications, and implant stability and survival. Results: Twenty (20) partially edentulous patients (9 males, 11 females; mean age 54.4 ± 9.4 years) were included in the study; 28 open, selective, tooth-supported templates were designed with the aim of inserting 38 implants. Among the surgical templates, 24 had optimal fit and stability, three had optimal fit and sufficient stability, and only one had inadequate fit and unsatisfactory stability and was therefore not suitable for clinical use. The average time of the intervention was 15.7 ± 5.2 min per template. No intra-operative complications were reported, but one implant was not stable at placement and had to be removed. In total, 36 implants were restored with 10 two-unit fixed partial prostheses and 16 single crowns. All implants were successfully functioning at one year, even if, in two single crowns, minor prosthetic complications (abutment screw loosening) occurred. Conclusions: Full in-office guided surgery with open, selective, tooth-supported templates seem to represent a clinically predictable surgical procedure to restore partially edentulous patients. Further studies are needed to confirm these positive outcomes.
Suggested Citation
Francesco Guido Mangano & Uli Hauschild & Oleg Admakin, 2018.
"Full in-Office Guided Surgery with Open Selective Tooth-Supported Templates: A Prospective Clinical Study on 20 Patients,"
IJERPH, MDPI, vol. 15(11), pages 1-20, October.
Handle:
RePEc:gam:jijerp:v:15:y:2018:i:11:p:2361-:d:178261
Download full text from publisher
Citations
Citations are extracted by the
CitEc Project, subscribe to its
RSS feed for this item.
Cited by:
- Luigi V. Stefanelli & George A. Mandelaris & Alessio Franchina & Nicola Pranno & Michele Pagliarulo & Francesca Cera & Fabio Maltese & Francesca De Angelis & Stefano Di Carlo, 2020.
"Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series,"
IJERPH, MDPI, vol. 17(14), pages 1-15, July.
- Francesco Mangano & Bidzina Margiani & Oleg Admakin, 2019.
"A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE ® ) for the Design and Fabrication of Implant-Supported Monolithic Translucent Zirconia Crowns Cemented on Customized Hybrid Abutments: A Retrospecti,"
IJERPH, MDPI, vol. 16(3), pages 1-20, January.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:15:y:2018:i:11:p:2361-:d:178261. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.