IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v14y2017i9p949-d109428.html
   My bibliography  Save this article

Exposure Modelling of Extremely Low-Frequency Magnetic Fields from Overhead Power Lines and Its Validation by Measurements

Author

Listed:
  • Alfred Bürgi

    (ARIAS umwelt.forschung.beratung gmbh, Gutenbergstrasse 40B, 3011 Bern, Switzerland
    Joint first authors.)

  • Sanjay Sagar

    (Swiss Tropical and Public Health Institute, Department of Epidemiology and Public Health, Socinstrasse 57, 4051 Basel, Switzerland
    University of Basel, Petersplatz 1, 4051 Basel, Switzerland
    Joint first authors.)

  • Benjamin Struchen

    (Swiss Tropical and Public Health Institute, Department of Epidemiology and Public Health, Socinstrasse 57, 4051 Basel, Switzerland
    University of Basel, Petersplatz 1, 4051 Basel, Switzerland)

  • Stefan Joss

    (Federal Office for the Environment (FOEN), 3003 Bern, Switzerland)

  • Martin Röösli

    (Swiss Tropical and Public Health Institute, Department of Epidemiology and Public Health, Socinstrasse 57, 4051 Basel, Switzerland
    University of Basel, Petersplatz 1, 4051 Basel, Switzerland)

Abstract

A three-dimensional model for calculating long term exposure to extremely low-frequency magnetic fields from high-voltage overhead power lines is presented, as well as its validation by measurements. For the validation, the model was applied to two different high-voltage overhead power lines in Iffwil and Wiler (Switzerland). In order to capture the daily and seasonal variations, each measurement was taken for 48 h and the measurements were carried out six times at each site, at intervals of approximately two months, between January and December 2015. During each measurement, a lateral transect of the magnetic flux density was determined in the middle of a span from nine measurement points in the range of ±80 m. The technical data of both the lines as well as the load flow data during the measurement periods were provided by the grid operators. These data were used to calculate 48 h averages of the absolute value of the magnetic flux density and compared with modelled values. The highest 48 h average was 1.66 µT (centre of the line in Iffwil); the lowest 48 h average was 22 nT (80 m distance from the centre line in Iffwil). On average, the magnetic flux density was overestimated by 2% (standard deviation: 9%) in Iffwil and underestimated by 1% (8%) in Wiler. Sensitivity analyses showed that the uncertainty is mainly driven by errors in the coordinates and height data. In particular, for predictions near the centre of the line, an accurate digital terrain model is critical.

Suggested Citation

  • Alfred Bürgi & Sanjay Sagar & Benjamin Struchen & Stefan Joss & Martin Röösli, 2017. "Exposure Modelling of Extremely Low-Frequency Magnetic Fields from Overhead Power Lines and Its Validation by Measurements," IJERPH, MDPI, vol. 14(9), pages 1-19, August.
  • Handle: RePEc:gam:jijerp:v:14:y:2017:i:9:p:949-:d:109428
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/14/9/949/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/14/9/949/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:14:y:2017:i:9:p:949-:d:109428. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.