Author
Listed:
- Cecylia Łukaszuk
(Department of Integrated Medical Care, Medical University of Bialystok, 15-274 Białystok, Poland)
- Elżbieta Krajewska-Kułak
(Department of Integrated Medical Care, Medical University of Bialystok, 15-274 Białystok, Poland)
- Andrzej Guzowski
(Department of Integrated Medical Care, Medical University of Bialystok, 15-274 Białystok, Poland)
- Wojciech Kułak
(Department of Pediatric Rehabilitation, Medical University of Białystok, 15-274 Białystok, Poland)
- Bogumiła Kraszyńska
(Department of Integrated Medical Care, Medical University of Bialystok, 15-274 Białystok, Poland)
Abstract
Although several air sampling devices for identifying and enumerating airborne microorganisms are commercially available, each poses some limitations. The aim of this study was to evaluate air pollution fungi using three such samplers: SAS Super 100, Microbiological Air Sampler (MAS) 100, and Air IDEAL. Mycological air was taken from the cellars of a 17th-century church in Siemiatycze, Poland, and the nearby outdoor environment. With samplers placed 1.5 m above the floor, microbial flora in air samples collected inside and outside the cellar were detected. The number of colony-forming units (CFU) of fungi obtained with the three samplers from the cellars and outdoor environment differed; the most CFU were obtained with the Air IDEAL and the least with the SAS Super 100. Significant differences emerged in CFUs collected from air samples with the MAS 100 and SAS Super 100, on the one hand, and the SAS Super 100 and Air IDEAL, on the other. Otherwise, results among the samplers were different. More Cladosporium species were collected with the MAS 100 sampler, whereas more Fusarium and Aspergillus species were collected with the Air IDEAL sampler. Significant differences among CFU/m 3 values among the tested sites depended on the sampler used.
Suggested Citation
Cecylia Łukaszuk & Elżbieta Krajewska-Kułak & Andrzej Guzowski & Wojciech Kułak & Bogumiła Kraszyńska, 2017.
"Comparison of the Results of Studies of Air Pollution Fungi Using the SAS Super 100, MAS 100, and Air IDEAL,"
IJERPH, MDPI, vol. 14(7), pages 1-7, July.
Handle:
RePEc:gam:jijerp:v:14:y:2017:i:7:p:815-:d:105287
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:14:y:2017:i:7:p:815-:d:105287. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.