IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v14y2017i2p128-d89006.html
   My bibliography  Save this article

Ultrafine and Fine Particulate Matter Inside and Outside of Mechanically Ventilated Buildings

Author

Listed:
  • Shelly L. Miller

    (Department of Mechanical Engineering; University of Colorado, Boulder, CO 80309, USA)

  • Nick A. Facciola

    (Department of Mechanical Engineering; University of Colorado, Boulder, CO 80309, USA)

  • Darin Toohey

    (Department of Atmospheric and Oceanic Sciences, University of Colorado, Boulder, CO 80309, USA)

  • John Zhai

    (Department of Civil, Environmental and Architectural Engineering, University of Colorado, Boulder, CO 80309, USA)

Abstract

The objectives of this study were to measure levels of particulate matter (PM) in mechanically ventilated buildings and to improve understanding of filtration requirements to reduce exposure. With the use of an Ultra High Sensitivity Aerosol Spectrometer and an Aerodyne Mass Spectrometer, ultrafine (0.055–0.1 μm) and fine (0.1–0.7 μm) indoor and outdoor PM was measured as a function of time in an office, a university building, and two elementary schools. Indoor particle levels were highly correlated with outdoor levels. Indoor and outdoor number concentrations in Denver were higher than those in Boulder, with the highest number concentrations occurring during summer and fall. The ratio of indoor-to-outdoor (I/O) PM was weakly but positively correlated with the amount of ventilation provided to the indoor environment, did not vary much with particle size (ranged between 0.48 and 0.63 for the entire size range), and was similar for each period of the week (weekend vs. weekday, night vs. day). Regression analyses showed that ultrafine indoor PM baseline concentrations were higher at night from nighttime infiltration. A lag time was observed between outdoor and indoor measurements. Weekday days had the shortest lag time of 11 min, and weekend nighttime lags when the HVAC was not in use were 50 to 148 min. Indoor-outdoor PM concentration plots showed ultrafine PM was more correlated compared to fine, and especially when the HVAC system was on. Finally, AMS data showed that most of the PM was organic, with occasional nitrate events occurring outdoors. During nitrate events, there were less indoor particles detected, indicating a loss of particulate phase nitrate. The results from this study show that improved filtration is warranted in mechanically ventilated buildings, particularly for ultrafine particles, and that nighttime infiltration is significant depending on the building design.

Suggested Citation

  • Shelly L. Miller & Nick A. Facciola & Darin Toohey & John Zhai, 2017. "Ultrafine and Fine Particulate Matter Inside and Outside of Mechanically Ventilated Buildings," IJERPH, MDPI, vol. 14(2), pages 1-17, January.
  • Handle: RePEc:gam:jijerp:v:14:y:2017:i:2:p:128-:d:89006
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/14/2/128/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/14/2/128/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:14:y:2017:i:2:p:128-:d:89006. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.