IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v14y2017i1p78-d87799.html
   My bibliography  Save this article

Evaluation of Potential Average Daily Doses (ADDs) of PM 2.5 for Homemakers Conducting Pan-Frying Inside Ordinary Homes under Four Ventilation Conditions

Author

Listed:
  • Seonyeop Lee

    (Department of Environmental Health Sciences, Soonchunhyang University, Asan 31538, Korea)

  • Sol Yu

    (Department of Environmental Health Sciences, Soonchunhyang University, Asan 31538, Korea)

  • Sungroul Kim

    (Department of Environmental Health Sciences, Soonchunhyang University, Asan 31538, Korea)

Abstract

Several studies reported that commercial barbecue restaurants likely contribute to the indoor emission of particulate matters with a diameter of 2.5 micrometers or less (PM 2.5 ) while pan-frying meat. However, there is inadequate knowledge of exposure level to indoor PM 2.5 in homes and the contribution of a typical indoor pan-frying event. We measured the indoor PM 2.5 concentration and, using Monte-Carlo simulation, estimated potential average daily dose (ADD) of PM 2.5 for homemakers pan-frying a piece of pork inside ordinary homes. Convenience-based sampling at 13 homes was conducted over four consecutive days in June 2013 ( n = 52). Although we pan-fried 100 g pork for only 9 min, the median (interquartile range, IQR) value was 4.5 (2.2–5.6) mg/m 3 for no ventilation and 0.5 (0.1–1.3) mg/m 3 with an active stove hood ventilation system over a 2 h sampling interval. The probabilities that the ADDs from inhalation of indoor PM 2.5 would be higher than the ADD from inhalation of PM 2.5 on an outdoor roadside (4.6 μg/kg·day) were 99.44%, 97.51%, 93.64%, and 67.23%, depending on the ventilation conditions: (1) no window open; (2) one window open in the kitchen; (3) two windows open, one each in the kitchen and living room; and (4) operating a forced-air stove hood, respectively.

Suggested Citation

  • Seonyeop Lee & Sol Yu & Sungroul Kim, 2017. "Evaluation of Potential Average Daily Doses (ADDs) of PM 2.5 for Homemakers Conducting Pan-Frying Inside Ordinary Homes under Four Ventilation Conditions," IJERPH, MDPI, vol. 14(1), pages 1-10, January.
  • Handle: RePEc:gam:jijerp:v:14:y:2017:i:1:p:78-:d:87799
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/14/1/78/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/14/1/78/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:14:y:2017:i:1:p:78-:d:87799. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.