Author
Listed:
- Shirin Davarpanah Jazi
(Human Threshold Research Group, Imaging Program, Lawson Health Research Institute, London, ON N6A 4V2, Canada
Department of Medical Biophysics, Western University, London, ON N6A 5C1, Canada)
- Julien Modolo
(Human Threshold Research Group, Imaging Program, Lawson Health Research Institute, London, ON N6A 4V2, Canada
LTSI U1099, INSERM, Université de Rennes, 35042 Rennes, France)
- Cadence Baker
(Human Threshold Research Group, Imaging Program, Lawson Health Research Institute, London, ON N6A 4V2, Canada
School of Kinesiology, Western University, London, ON N6A 3K7, Canada)
- Sebastien Villard
(Human Threshold Research Group, Imaging Program, Lawson Health Research Institute, London, ON N6A 4V2, Canada
Department of Medical Biophysics, Western University, London, ON N6A 5C1, Canada)
- Alexandre Legros
(Human Threshold Research Group, Imaging Program, Lawson Health Research Institute, London, ON N6A 4V2, Canada
Department of Medical Biophysics, Western University, London, ON N6A 5C1, Canada
School of Kinesiology, Western University, London, ON N6A 3K7, Canada
Department of Medical Imaging, Western University, London, ON N6A 5W9, Canada)
Abstract
Humans are surrounded by sources of daily exposure to power-frequency (60 Hz in North America) magnetic fields (MFs). Such time-varying MFs induce electric fields and currents in living structures which possibly lead to biological effects. The present pilot study examined possible extremely low frequency (ELF) MF effects on human neuromotor control in general, and physiological postural tremor and electroencephalography (EEG) in particular. Since the EEG cortical mu-rhythm (8–12 Hz) from the primary motor cortex and physiological tremor are related, it was hypothesized that a 60 Hz MF exposure focused on this cortical region could acutely modulate human physiological tremor. Ten healthy volunteers (age: 23.8 ± 4 SD) were fitted with a MRI-compatible EEG cap while exposed to 11 MF conditions (60 Hz, 0 to 50 mT rms , 5 mT rms increments). Simultaneously, physiological tremor (recorded from the contralateral index finger) and EEG (from associated motor and somatosensory brain regions) were measured. Results showed no significant main effect of MF exposure conditions on any of the analyzed physiological tremor characteristics. In terms of EEG, no significant effects of the MF were observed for C1, C3, C5 and CP1 electrodes. However, a significant main effect was found for CP3 and CP5 electrodes, both suggesting a decreased mu-rhythm spectral power with increasing MF flux density. This is however not confirmed by Bonferroni corrected pairwise comparisons. Considering both EEG and tremor findings, no effect of the MF exposure on human motor control was observed. However, MF exposure had a subtle effect on the mu-rhythm amplitude in the brain region involved in tactile perception. Current findings are to be considered with caution due to the small size of this pilot work, but they provide preliminary insights to international agencies establishing guidelines regarding electromagnetic field exposure with new experimental data acquired in humans exposed to high mT-range MFs.
Suggested Citation
Shirin Davarpanah Jazi & Julien Modolo & Cadence Baker & Sebastien Villard & Alexandre Legros, 2017.
"Effects of A 60 Hz Magnetic Field of Up to 50 milliTesla on Human Tremor and EEG: A Pilot Study,"
IJERPH, MDPI, vol. 14(12), pages 1-11, November.
Handle:
RePEc:gam:jijerp:v:14:y:2017:i:12:p:1446-:d:120196
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:14:y:2017:i:12:p:1446-:d:120196. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.