Author
Listed:
- Matteo Iervolino
(Department of Biological, Geological and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy)
- Benedetta Mancini
(Department of Biological, Geological and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy)
- Sandra Cristino
(Department of Biological, Geological and Environmental Sciences, BiGeA, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy)
Abstract
The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS). Environmental monitoring of Legionella , P. aeruginosa , and a heterotrophic plate count (HPC) at 36 °C was performed from June to October 2016. The disinfection procedures adopted were based on hydrogen peroxide (H 2 O 2 ) and silver salts (Ag + ), in addition to an anti-algal treatment, then using hyperclorination as a shock, and then continuous treatment by sodium hypochlorite (NaClO). L . pneumophila serogroup 8 was found at a concentration of 5.06 Log cfu/L after the CTS filling; a shock treatment performed by H 2 O 2 /Ag + produced a rapid increase in contamination up to 6.14 Log cfu/L. The CTS activity was stopped and two subsequent shock treatments were performed using NaClO, followed by continuous hyperclorination. These procedures showed a significant decrease ( p < 0.05) in Legionella concentration (1.77 Log cfu/L). The same trend was observed for P . aeruginosa (0.55 Log cfu/100 mL) and HPC (1.95 Log cfu/mL) at 36 °C. Environmental monitoring and the adoption of maintenance procedures, including anti-scale treatment, and physical, chemical, and microbiological control, ensure the good performance of a CTS, reducing the Legionella risk for public health.
Suggested Citation
Matteo Iervolino & Benedetta Mancini & Sandra Cristino, 2017.
"Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp,"
IJERPH, MDPI, vol. 14(10), pages 1-14, September.
Handle:
RePEc:gam:jijerp:v:14:y:2017:i:10:p:1125-:d:113307
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:14:y:2017:i:10:p:1125-:d:113307. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.