Author
Listed:
- Lijie Li
(Shijiazhuang Center for Disease Control and Prevention, No.3, Likang Street, Shijiazhuang 050011, China
These authors contributed equally to this work.)
- Tian Qin
(State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, No. 155, Changbai Road, Changping, Beijing 102206, China
Collaborative Innovation Centre for Diagnosis and Treatment of Infectious Diseases, Hangzhou 310003, China
These authors contributed equally to this work.)
- Yun Li
(Hebei International Travel Health-Care Center, No.409-1, Hongqi Stree, Shijiazhuang 050000, China)
- Haijian Zhou
(State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, No. 155, Changbai Road, Changping, Beijing 102206, China
Collaborative Innovation Centre for Diagnosis and Treatment of Infectious Diseases, Hangzhou 310003, China)
- Hongmei Song
(Shijiazhuang Center for Disease Control and Prevention, No.3, Likang Street, Shijiazhuang 050011, China)
- Hongyu Ren
(State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, No. 155, Changbai Road, Changping, Beijing 102206, China
Collaborative Innovation Centre for Diagnosis and Treatment of Infectious Diseases, Hangzhou 310003, China)
- Liping Li
(Shijiazhuang Center for Disease Control and Prevention, No.3, Likang Street, Shijiazhuang 050011, China)
- Yongguang Li
(Shijiazhuang Jiyuan Environmental Protection Technology Co.Ltd, Shijiazhuang 050035, China)
- Dong Zhao
(Shijiazhuang Center for Disease Control and Prevention, No.3, Likang Street, Shijiazhuang 050011, China)
Abstract
Cooling towers are a source of Legionnaires’ disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella . Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella- positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila , and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA , are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed.
Suggested Citation
Lijie Li & Tian Qin & Yun Li & Haijian Zhou & Hongmei Song & Hongyu Ren & Liping Li & Yongguang Li & Dong Zhao, 2015.
"Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments,"
IJERPH, MDPI, vol. 12(10), pages 1-13, October.
Handle:
RePEc:gam:jijerp:v:12:y:2015:i:10:p:12605-12617:d:56966
Download full text from publisher
Citations
Citations are extracted by the
CitEc Project, subscribe to its
RSS feed for this item.
Cited by:
- Noriko Nakanishi & Ryohei Nomoto & Shinobu Tanaka & Kentaro Arikawa & Tomotada Iwamoto, 2019.
"Analysis of Genetic Characterization and Clonality of Legionella pneumophila Isolated from Cooling Towers in Japan,"
IJERPH, MDPI, vol. 16(9), pages 1-9, May.
- Leyi Zhang & Yi Li & Xin Wang & Zhihui Shangguan & Haijian Zhou & Yuejin Wu & Lianghuai Wang & Hongyu Ren & Yun Hu & Meifen Lin & Tian Qin, 2017.
"High Prevalence and Genetic Polymorphisms of Legionella in Natural and Man-Made Aquatic Environments in Wenzhou, China,"
IJERPH, MDPI, vol. 14(3), pages 1-13, February.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:12:y:2015:i:10:p:12605-12617:d:56966. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.