IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v10y2013i2p541-555d23279.html
   My bibliography  Save this article

Assessment of the Levels of Airborne Bacteria, Gram-Negative Bacteria, and Fungi in Hospital Lobbies

Author

Listed:
  • Dong-Uk Park

    (Department of Environmental Health, Korea National Open University, Seoul, 110-791, Korea)

  • Jeong-Kwan Yeom

    (Hanbul Energy Manufacturing, Sampyeong-Dong, Bundang-Gu, Gyeonggido, 463-413, Korea
    Department of Global Healthcare Management, Gachon University, Gyeonggido, 461-701, Korea)

  • Won Jae Lee

    (Department of Global Healthcare Management, Gachon University, Gyeonggido, 461-701, Korea)

  • Kyeong-Min Lee

    (Department of Environmental Health, Korea National Open University, Seoul, 110-791, Korea
    Institute for Occupational Health & Graduate School of Public Health, Yonsei University, Seoul, 120-752, Korea)

Abstract

Aims: We assessed the levels of airborne bacteria, Gram-negative bacteria (GNB), and fungi in six hospital lobbies, and investigated the environmental and hospital characteristics that affected the airborne microorganism levels. Methods: An Andersen single-stage sampler equipped with appropriate nutrition plate agar was used to collect the samples. The three types of microorganisms were repeatedly collected at a fixed location in each hospital (assumed to be representative of the entire hospital lobby) from 08:00 through 24:00, with a sampling time of less than 5 min. Temperature and relative humidity were simultaneously monitored. Results: Multiple regression analysis was used to identify the major factors affecting microorganism levels. The average levels of bacteria (7.2 × 10 2 CFU/m 3 ), GNB (1.7 × 10 CFU/m 3 ), and fungi (7.7 × 10 CFU/m 3 ) indicated that all hospital lobbies were generally contaminated. Season was the only factor that significantly affected the levels of all microorganisms ( p < 0.0001), where contamination was the highest during the summer, significantly higher than during the winter. Other significant factors varied by microorganism, as follows: airborne bacteria (number of people in the lobby, sampling time), GNB (scale of hospital), and fungi (humidity and air temperature). Conclusions: Hospital lobby air was generally contaminated with microorganisms, including bacteria, GNB, and fungi. Environmental factors that may significantly influence the airborne concentrations of these agents should be managed to minimize airborne levels.

Suggested Citation

  • Dong-Uk Park & Jeong-Kwan Yeom & Won Jae Lee & Kyeong-Min Lee, 2013. "Assessment of the Levels of Airborne Bacteria, Gram-Negative Bacteria, and Fungi in Hospital Lobbies," IJERPH, MDPI, vol. 10(2), pages 1-15, January.
  • Handle: RePEc:gam:jijerp:v:10:y:2013:i:2:p:541-555:d:23279
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/10/2/541/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/10/2/541/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Sung-Yeon Cho & Jun-Pyo Myong & Won-Bok Kim & Chulmin Park & Sung Jeon Lee & Sang Hyeon Lee & Dong-Gun Lee, 2018. "Profiles of Environmental Mold: Indoor and Outdoor Air Sampling in a Hematology Hospital in Seoul, South Korea," IJERPH, MDPI, vol. 15(11), pages 1-12, November.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:10:y:2013:i:2:p:541-555:d:23279. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.