IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v10y2013i1p347-360d22776.html
   My bibliography  Save this article

Evaluation of Full-Facepiece Respirator Fit on Fire Fighters in the Municipality of Jeddah, Saudi Arabia

Author

Listed:
  • Mansour A. Balkhyour

    (Department of Environmental Sciences, Faculty of Meteorology, Environment and Arid Land Agriculture, King Abdulaziz University, P.O. Box 80208, Jeddah 21589, Saudi Arabia)

Abstract

The purpose of this study was to assess the effect of personal variables on the fit of the respirators used by firefighters and workers in highly polluted environments. However, resistance from many plants managers was met to conduct the study on their workers. Therefore, we were forced to limit the study on firefighters who were found very cooperative. Forty volunteer firefighters from different departments participated in the study. They were subjected to a daily leak rate measurement using a Control Negative Pressure (CNP) fit tester for five consecutive days. Two types of respirators were used for each volunteer: the Drager type and the MSA. At the end of the study, the association between face shape and presence of beard with the respirator leak rates was investigated. A significant difference in the leak rate was detected between the two types of respirators used, with the Drager respirator having higher leak rates. The presence of a beard increased dramatically the leak rate whatever the face shape was. The oval shape was the best fitting to the respirators, followed by the rounded and finally the rectangular face. The study recommends that personal variables like face shape must be taken into consideration and fit testing must be carried out periodically, to specify the respirator that best fits each firefighter. Having beard must be absolutely prohibited, since it can be life threatening in environmental dangerous conditions such those encountered during extinguishing fires and overhaul situations.

Suggested Citation

  • Mansour A. Balkhyour, 2013. "Evaluation of Full-Facepiece Respirator Fit on Fire Fighters in the Municipality of Jeddah, Saudi Arabia," IJERPH, MDPI, vol. 10(1), pages 1-14, January.
  • Handle: RePEc:gam:jijerp:v:10:y:2013:i:1:p:347-360:d:22776
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/10/1/347/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/10/1/347/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:10:y:2013:i:1:p:347-360:d:22776. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.