IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v5y2012i10p3817-3834d20359.html
   My bibliography  Save this article

Integrated Coordinated Optimization Control of Automatic Generation Control and Automatic Voltage Control in Regional Power Grids

Author

Listed:
  • Qiu-Yu Lu

    (State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China)

  • Wei Hu

    (State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China)

  • Le Zheng

    (State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China)

  • Yong Min

    (State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China)

  • Miao Li

    (Hubei Electrical Power Co. Ltd., Wuhan, Hubei 430077, China)

  • Xiao-Ping Li

    (Hubei Electrical Power Co. Ltd., Wuhan, Hubei 430077, China)

  • Wei-Chun Ge

    (Liaoning Electrical Power Co. Ltd., Shenyang, Liaoning 110006, China)

  • Zhi-Ming Wang

    (Liaoning Electrical Power Co. Ltd., Shenyang, Liaoning 110006, China)

Abstract

Automatic Generation Control (AGC) and Automatic Voltage Control (AVC) are key approaches to frequency and voltage regulation in power systems. However, based on the assumption of decoupling of active and reactive power control, the existing AGC and AVC systems work independently without any coordination. In this paper, a concept and method of hybrid control is introduced to set up an Integrated Coordinated Optimization Control (ICOC) system for AGC and AVC. Concerning the diversity of control devices and the characteristics of discrete control interaction with a continuously operating power system, the ICOC system is designed in a hierarchical structure and driven by security, quality and economic events, consequently reducing optimization complexity and realizing multi-target quasi-optimization. In addition, an innovative model of Loss Minimization Control (LMC) taking into consideration active and reactive power regulation is proposed to achieve a substantial reduction in network losses and a cross iterative method for AGC and AVC instructions is also presented to decrease negative interference between control systems. The ICOC system has already been put into practice in some provincial regional power grids in China. Open-looping operation tests have proved the validity of the presented control strategies.

Suggested Citation

  • Qiu-Yu Lu & Wei Hu & Le Zheng & Yong Min & Miao Li & Xiao-Ping Li & Wei-Chun Ge & Zhi-Ming Wang, 2012. "Integrated Coordinated Optimization Control of Automatic Generation Control and Automatic Voltage Control in Regional Power Grids," Energies, MDPI, vol. 5(10), pages 1-18, September.
  • Handle: RePEc:gam:jeners:v:5:y:2012:i:10:p:3817-3834:d:20359
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/5/10/3817/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/5/10/3817/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Ming-Tse Kuo & Shiue-Der Lu, 2013. "Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line Limits," Energies, MDPI, vol. 6(7), pages 1-21, July.
    2. Mahmut Temel ÖZDEMİR & Dursun ÖZTÜRK, 2017. "Comparative Performance Analysis of Optimal PID Parameters Tuning Based on the Optics Inspired Optimization Methods for Automatic Generation Control," Energies, MDPI, vol. 10(12), pages 1-19, December.
    3. Mi Dong & Li Li & Lina Wang & Dongran Song & Zhangjie Liu & Xiaoyu Tian & Zhengguo Li & Yinghua Wang, 2018. "A Distributed Secondary Control Algorithm for Automatic Generation Control Considering EDP and Automatic Voltage Control in an AC Microgrid," Energies, MDPI, vol. 11(4), pages 1-18, April.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:5:y:2012:i:10:p:3817-3834:d:20359. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.