Author
Listed:
- Long Peng
(China Electric Power Research Institute, Haidian District, Beijing 100192, China)
- Shiyun Xu
(China Electric Power Research Institute, Haidian District, Beijing 100192, China)
- Zeyuan An
(School of Electrical Engineering, Northeast Electric Power University, Jilin 132012, China)
- Yi Wang
(School of Electrical Engineering, Northeast Electric Power University, Jilin 132012, China)
- Bo Wang
(School of Electrical Engineering, Northeast Electric Power University, Jilin 132012, China)
Abstract
In practical engineering, it has been observed that increasing local generators’ capacity in receiving-end power grids can lead the system to transition from voltage instability to power angle instability after a fault. This contradicts the typical engineering experience, where increasing the generators’ capacity at the receiving end is expected to enhance voltage stability, making it challenging to define an appropriate pre-control range for generators. This paper aims to quantify the impact of local generators on the stability of AC/DC receiving-end power grids. First, the paper describes the instability phenomena observed under different generators’ capacity conditions in actual AC/DC receiving-end power grids. Next, by using a simplified single-machine-load-infinite-bus model, the paper explores how the system’s instability characteristics evolve from being dominated by load instability to being driven by generator instability as the ratio of local generators to load varies. This study conducts an in-depth analysis of the coupling mechanism between power angle stability and voltage stability. For the first time, it quantitatively characterizes the stable operating region of the system using power angle and induction motor slip as dual constraint conditions, providing a new theoretical framework for power system stability analysis. Additionally, addressing the lack of quantitative research on the upper limit of generator operation in current systems, this study constructs post-fault power recovery curves for loads and DC power sources. Based on the equal-area criterion, it proposes a quantitative index for the upper limit of local generator operation, filling a research gap in this field and providing a crucial theoretical basis and reference for practical power system operation and dispatch.
Suggested Citation
Long Peng & Shiyun Xu & Zeyuan An & Yi Wang & Bo Wang, 2025.
"Research on the Quantitative Impact of Power Angle Oscillations on Transient Voltage Stability in AC/DC Receiving-End Power Grids,"
Energies, MDPI, vol. 18(8), pages 1-18, April.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:8:p:1925-:d:1631702
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:8:p:1925-:d:1631702. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.