IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v18y2025i7p1683-d1622051.html
   My bibliography  Save this article

Quantitative Difference Between the Effective Inertia and Set Inertia Parameter of Virtual Synchronous Generators

Author

Listed:
  • Ryosuke Shikuma

    (Department of Advanced Science and Engineering, Waseda University, 3-4-1-63-6A Okubo, Shinjuku-ku, Tokyo 169-8555, Japan)

  • Dai Orihara

    (Renewable Energy Research Center, National Institute of Advanced Industrial Science and Technology, 2-2-9 Machiikedai, Koriyama 963-0298, Japan)

  • Hiroshi Kikusato

    (Renewable Energy Research Center, National Institute of Advanced Industrial Science and Technology, 2-2-9 Machiikedai, Koriyama 963-0298, Japan)

  • Akihisa Kaneko

    (Advanced Collaborative Research Organization for Smart Society (ACROSS), Waseda University, Tokyo 169-8555, Japan)

  • Hisao Taoka

    (Renewable Energy Research Center, National Institute of Advanced Industrial Science and Technology, 2-2-9 Machiikedai, Koriyama 963-0298, Japan)

  • Yasuhiro Hayashi

    (Department of Advanced Science and Engineering, Waseda University, 3-4-1-63-6A Okubo, Shinjuku-ku, Tokyo 169-8555, Japan)

Abstract

Virtual synchronous generators (VSGs) have been developed to mitigate the increase in the rate of change of frequency (ROCOF) in power systems by replacing synchronous generators (SGs) with inverter-based resources. VSGs mimic the dynamics and control of SGs; however, the mechanical delay typical of an SG’s turbine is often excluded, limiting improvements to the VSG’s response. The fast frequency response (FFR) of VSGs can help reduce ROCOF and enhance emulated inertia. This implies that the effective inertia (EI) of VSGs can exceed the set inertia parameter, posing challenges for operators in allocating sufficient VSG capacity considering the inertia required for stable operation. In this study, we quantitatively analyzed the difference between the EI of a VSG and the set inertia parameter by separating the active power output into inertia and governor responses. The quantitative analysis revealed that when the VSG provides FFR within the inertia-time domain, the EI exceeds the set inertia parameter. Furthermore, the sensitivities of the VSG set parameters and VSG capacity ratio, which is related to synchronizing power coefficients and the initial sharing ratio, for the EI were analyzed. These factors were theoretically considered, and the simulations validated their characteristics.

Suggested Citation

  • Ryosuke Shikuma & Dai Orihara & Hiroshi Kikusato & Akihisa Kaneko & Hisao Taoka & Yasuhiro Hayashi, 2025. "Quantitative Difference Between the Effective Inertia and Set Inertia Parameter of Virtual Synchronous Generators," Energies, MDPI, vol. 18(7), pages 1-23, March.
  • Handle: RePEc:gam:jeners:v:18:y:2025:i:7:p:1683-:d:1622051
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/18/7/1683/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/18/7/1683/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:7:p:1683-:d:1622051. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.