Author
Listed:
- Jing Chen
(Beijing Electric Power Economic and Technological Research Institute Co., Ltd., Beijing 100055, China)
- Xiaoyue Chen
(School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China)
- Siying Feng
(School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China)
- Xinmeng Liu
(Beijing Electric Power Economic and Technological Research Institute Co., Ltd., Beijing 100055, China)
- Qin Liu
(Beijing Electric Power Economic and Technological Research Institute Co., Ltd., Beijing 100055, China)
Abstract
When a 35 kV distribution network has the problem of insufficient reactive power, the input of a shunt reactor is a common compensation method. Vacuum circuit breakers are widely used in 35 kV distribution networks because of their superior arc extinguishing performance and convenient maintenance. However, in recent years, accidents involving vacuum circuit breakers breaking shunt reactors have occurred more frequently in China, such as high-frequency phase-to-phase short circuits, inter-turn burning losses, bus outlet short circuits, etc., which can cause serious damage and pose a greater threat to the safety of the power system. This paper focuses on the switching overvoltage generated by the vacuum circuit breaker cutting off the shunt reactor. Firstly, the mechanism of overvoltage generation is analyzed theoretically. It is concluded that the equivalent chopping current of the other two phases caused by the continuous reignition of the first open phase is the root cause of the high-amplitude interphase overvoltage. Based on the MODELS custom programming module in EMTP/ATP, according to the process of breaking and reigniting the circuit breaker, this paper uses Fortran language to compile the program and establishes a model of a vacuum circuit breaker, including power frequency current interception, high-frequency current, zero-crossing, breaking, and arc reignition modules. The vacuum circuit breaker is simulated for hundreds of continuous reignitions in milliseconds. Finally, a simulation study on the overvoltage suppression measures of a 35 kV shunt reactor is carried out. The comprehensive comparison of various suppression measures provides a reference for the reasonable selection of actual engineering conditions.
Suggested Citation
Jing Chen & Xiaoyue Chen & Siying Feng & Xinmeng Liu & Qin Liu, 2025.
"Overvoltage Simulation Analysis and Suppression of Breaking in a 35 kV Shunt Reactor,"
Energies, MDPI, vol. 18(5), pages 1-17, March.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:5:p:1274-:d:1605906
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:5:p:1274-:d:1605906. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.