Author
Listed:
- Jun Zhao
(Electric Power Research Institute, State Grid Hebei Electric Power Company, Shijiazhuang 050000, China)
- Chao Xing
(Electric Power Research Institute, State Grid Hebei Electric Power Company, Shijiazhuang 050000, China)
- Zhigang Zhang
(Electric Power Research Institute, State Grid Hebei Electric Power Company, Shijiazhuang 050000, China)
- Boyuan Liang
(Electric Power Research Institute, State Grid Hebei Electric Power Company, Shijiazhuang 050000, China)
- Lu Sun
(Electric Power Research Institute, State Grid Hebei Electric Power Company, Shijiazhuang 050000, China)
- Bin Wei
(State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China)
- Weiqi Qin
(State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China)
- Shuguo Gao
(Electric Power Research Institute, State Grid Hebei Electric Power Company, Shijiazhuang 050000, China)
Abstract
This paper proposes a novel optimization method for fault current limiter (FCL) reactance configuration based on joint simulation and penalty function constraint optimization. By integrating MATLAB and ATP for joint simulation, the method accurately derives the constraint conditions of the objective optimization function, providing critical data support for the optimization process. To address the challenges of high computational complexity and solution difficulties in constrained optimization, the Penalty Function Method (PFM) is employed to transform the original constrained optimization problem into a standard unconstrained optimization problem, significantly reducing computational complexity and ensuring the feasibility of the solution. On this basis, the Gravitational Search Algorithm (GSA) is applied to compute the optimal reactance value. Through comparative analysis of engineering case studies, the superiority of the GSA over the Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) in optimization performance is validated, further confirming the accuracy and efficiency of the proposed method. The results indicate that this method not only achieves precise calculation results but also significantly improves computational efficiency. Moreover, the integration of PFM and GSA demonstrates excellent robustness, providing reliable technical support for the optimized deployment of fast-switching fault current limiters in large-scale power grids.
Suggested Citation
Jun Zhao & Chao Xing & Zhigang Zhang & Boyuan Liang & Lu Sun & Bin Wei & Weiqi Qin & Shuguo Gao, 2025.
"Optimization of Fault Current Limiter Reactance Based on Joint Simulation and Penalty Function-Constrained Algorithm,"
Energies, MDPI, vol. 18(5), pages 1-16, February.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:5:p:1077-:d:1597645
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:5:p:1077-:d:1597645. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.