Underground and submarine power cables are subjected to mechanical stress during installation and operation, which degrades the cable insulation and reduces the reliability of power transmission. Therefore, tests that can evaluate the mechanical properties of power cable insulation are very important. The purpose of this paper is to introduce an improved sampling method for the test sample, the peeling, for mechanical testing of power cable insulation and to evaluate the reliability of the method. The influence of the sampling method of the test sample on the mechanical property values was analyzed. The tensile strength and elongation of XLPE (cross-linked polyethylene) and PP (polypropylene) insulation prepared by the slice method and the peeling method were measured, and the surface of the test samples according to the sampling methods was photographed by SEM. The results show that the mechanical property of the cable insulation increased by more than 10% when the improved peeling method was used, and the precision of the peeling method was relatively better. The SEM analysis showed that the surface of the sliced test sample was rougher than the peeled test sample and was physically damaged. Therefore, the high reliability of the peeling method for mechanical testing of cable insulators was demonstrated.
Suggested Citation
Seung-Won Lee & Jin-Wook Choe & Ik-Su Kwon & Jin-Seok Lim & Byung-Bae Park & Hae-Jong Kim, 2025.
"Reliability Evaluation of Improved Sampling Method for Mechanical Test of Cable Insulation,"
Energies, MDPI, vol. 18(4), pages 1-15, February.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:4:p:982-:d:1593872
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:4:p:982-:d:1593872. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.