Author
Listed:
- Linqing Zhang
(School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China)
- Yingrong Lu
(Department of Propulsion Engineering, Xiamen University, Xiamen 361005, China)
- Qinghuang Huang
(Department of Propulsion Engineering, Xiamen University, Xiamen 361005, China)
- Peiyong Wang
(Department of Propulsion Engineering, Xiamen University, Xiamen 361005, China)
- Juntao Chang
(School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China)
Abstract
C-type thermocouples are widely used to measure rich combustions; however, the measured temperature, i.e., the thermocouple junction temperature, is not equal to the gas temperature. The junction temperature results from the junction energy balance, including radiation with environments, conduction with thermocouple wires, and convection with gas. A correction based on the junction energy conservation can derive the gas temperature from the measured temperature. Two C-type thermocouples are used to measure the core region of the standard flames with known gas velocity, composition, and temperature. By matching the CFD-simulated junction temperature with the measured temperature, the emissivity of the thermocouples is obtained. In the temperature range of 1190–1542 K, the emissivity of both thermocouples is close to 0.4. Since the junctions of the C-type thermocouple are large, the area ratios of the wire cross-section to the junction surface are small, and the wire conduction effect is minimal. CFD simulations show that the junction temperatures only decrease by 3.9 K and 8.1 K without wire conduction when the 0.5 mm and 1.0 mm thermocouples measure the Hencken flame with the temperature of 2023.5 K. With the CFD simulation of the measurement of the diffusion region of the Hencken flame, where a strong gas temperature gradient exists, the junction contacting status is judged for the 0.5 mm thermocouple. The simulated temperature of the welding point is consistent with the measured temperature, indicating no wire contact inside the junction.
Suggested Citation
Linqing Zhang & Yingrong Lu & Qinghuang Huang & Peiyong Wang & Juntao Chang, 2025.
"Investigation of Emissivity and Junction Contacting Status of C-Type Thermocouples Using Rich Hencken Flames,"
Energies, MDPI, vol. 18(3), pages 1-15, January.
Handle:
RePEc:gam:jeners:v:18:y:2025:i:3:p:468-:d:1572638
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2025:i:3:p:468-:d:1572638. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.