Abstract
This paper presents a novel methodology to estimate the harmonic transfer impedances in electric power systems with multiple harmonic sources (HSs). The purpose is to determine the responsibility of each HS for the total harmonic distortion at a specific bus within the system, addressing a critical issue in the power quality field. To achieve this objective, it is necessary to estimate not only the individual HS, but also the transfer impedances between each source and the bus under analysis (BUA). Most methods for solving this problem are based on proper network modeling or restrict variations in harmonic sources to a single source at a time. The proposed methodology has overcome this limitation. For this, synchronized current and voltage phasors are measured at the BUA. Once the measurements are gathered, the Independent Component Analysis (ICA) method is applied to estimate the Norton equivalent. The harmonic transfer impedance (HTI) is then determined using the information provided by the ICA. To enhance the accuracy of HTI estimation, three procedures are employed for data mining the parameters provided by ICA over time to generate a well-conditioned system. Once the HTI is satisfactorily determined, the individual harmonic contributions (IHCs), i.e., the harmonic responsibility, can be estimated accurately. The effectiveness and performance of the method are demonstrated based on computational simulations using distribution and transmission systems. Additionally, the methodology is validated with real data collected from a Brazilian transmission system monitored by synchronized power quality measurement units. Simulated results show that the Total Vector Error (TVE) is less than 0.4%, and for the field data test, the TVE is less than 2%.
Suggested Citation
Mateus M. de Oliveira & Leandro R. M. Silva & Igor D. Melo & Carlos A. Duque & Paulo F. Ribeiro, 2024.
"Independent Component Analysis-Based Harmonic Transfer Impedance Estimation for Networks with Multiple Harmonic Sources,"
Energies, MDPI, vol. 18(1), pages 1-26, December.
Handle:
RePEc:gam:jeners:v:18:y:2024:i:1:p:85-:d:1555481
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:18:y:2024:i:1:p:85-:d:1555481. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.