IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v17y2024i5p1208-d1350415.html
   My bibliography  Save this article

Multiple Factors Coupling Probability Calculation Model of Transmission Line Ice-Shedding

Author

Listed:
  • Hao Pan

    (Joint Laboratory of Power Remote Sensing Technology, Electric Power Research Institute, Yunnan Power Grid Company Ltd., Kunming 650217, China)

  • Fangrong Zhou

    (Joint Laboratory of Power Remote Sensing Technology, Electric Power Research Institute, Yunnan Power Grid Company Ltd., Kunming 650217, China)

  • Yi Ma

    (Joint Laboratory of Power Remote Sensing Technology, Electric Power Research Institute, Yunnan Power Grid Company Ltd., Kunming 650217, China)

  • Yutang Ma

    (Joint Laboratory of Power Remote Sensing Technology, Electric Power Research Institute, Yunnan Power Grid Company Ltd., Kunming 650217, China)

  • Ping Qiu

    (Zhaotong Power Supply Bureau of Yunnan Power Grid Co., Ltd., Zhaotong 657000, China)

  • Jun Guo

    (School of Civil and Hydraulic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China)

Abstract

After a transmission line is covered by ice in winter, ice-shedding and vibration occurs under special meteorological and external dynamic conditions, which leads to intense transmission line shaking. Transmission line ice-shedding and vibration often cause line flashover trips and outages. In January 2018, three 500 kV transmission lines, namely, the 500 kV Guanli line, the 500 kV Dushan line, and the 500 kV Guanqiao line, tripped and cut off due to ice-shedding and vibration in Anhui province, seriously threatening the safe operation of a large power grid. Current studies mainly focus on analyzing the influence factors and characteristics of line ice-shedding and investigating suppression measures, but they only analyze the correlation between each influencing factor and icing or shedding, and do not consider the coupling effects between multiple factors. In this paper, the key influencing factors and the probability distribution of transmission line ice-shedding were analyzed, and a multiple-factor coupling fault probability calculation model of line ice-shedding based on Copula function was proposed. The fault probability was calculated directly by considering multiple influence factors at the same time, which effectively overcame the error caused by multi-factor transformation in fuzzy membership degree and other methods. It provided an important decision-making basis for preventing and controlling transmission line ice-shedding faults.

Suggested Citation

  • Hao Pan & Fangrong Zhou & Yi Ma & Yutang Ma & Ping Qiu & Jun Guo, 2024. "Multiple Factors Coupling Probability Calculation Model of Transmission Line Ice-Shedding," Energies, MDPI, vol. 17(5), pages 1-24, March.
  • Handle: RePEc:gam:jeners:v:17:y:2024:i:5:p:1208-:d:1350415
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/17/5/1208/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/17/5/1208/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Jiazheng Lu & Jun Guo & Jianping Hu & Li Yang & Tao Feng, 2017. "Analysis of ice disasters on ultra-high-voltage direct-current transmission lines," Natural Hazards: Journal of the International Society for the Prevention and Mitigation of Natural Hazards, Springer;International Society for the Prevention and Mitigation of Natural Hazards, vol. 86(1), pages 203-217, March.
    2. Yunyun Xie & Linyan Huang & Da Wang & Huaiping Ding & Xiaochun Yin, 2019. "Modeling and Analysis of Progressive Ice Shedding along a Transmission Line during Thermal De-Icing," Mathematical Problems in Engineering, Hindawi, vol. 2019, pages 1-12, June.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Hualong Zheng & Yizhang Wang & Dexin Xie & Zhijin Zhang & Xingliang Jiang, 2024. "Analysis of Solar Radiation Differences for High-Voltage Transmission Lines on Micro-Terrain Areas," Energies, MDPI, vol. 17(7), pages 1-16, April.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:5:p:1208-:d:1350415. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.