Author
Listed:
- Jin-Hee Kim
(Green Energy Technology Research Center, Kongju National University, Cheonan 31080, Republic of Korea)
- Sang-Myung Kim
(Department of Energy Systems Engineering, Graduate School of Energy Systems Engineering, Kongju National University, Cheonan 31080, Republic of Korea)
- Jun-Tae Kim
(Department of Smart Green Architectural Engineering & Energy Systems Engineering, Kongju National University, Cheonan 31080, Republic of Korea)
Abstract
The insulation performance of a building is one of the most fundamental factors in reducing its energy use. The insulation of the building envelope is the main factor that directly affects the cooling and heating loads, which is responsible for the largest portion of the building’s energy consumption. Recently, in South Korea, building insulation materials such as PIR and PF, which have not only fire resistance but also high insulation performance, are becoming mainstream in the industry as fire safety standards have been strengthened. However, there are concerns about the long-term change of high-performance insulation materials. In particular, in contrast with existing plastic insulation materials such as EPS and XPS, the evaluation of the reliability of the long-term change of insulation materials with a high closed-cell rate is becoming an issue. This is because, unlike the existing EPS and XPS, there are insufficient international standard test methods for evaluating the long-term thermal performance of composite insulation materials such as polyurethane and phenol. They are combined with layers of other types of thermal insulation and/or one or both of the surfaces are covered with coatings, facings, membranes or other surface skins, all serving some functional purpose depending on the product application. In this study, the long-term change of building insulation materials was tested and analyzed based on the standard of the accelerated aging test. Four types of building insulation materials were used in the experiment: EPS, XPS, PF and PIR. The accelerated aging tests were conducted based on ISO 11561 and BS EN 13166 standards (accelerated laboratory test methods). The results of the accelerated aging tests for the materials were analyzed and the thermal resistance of the insulation materials was also compared. From the test results according to the slicing test method specified in the ISO 11561, the thermal resistance of EPS, XPS, PF, and PIR with long-term changes decreased by 2.4%, 8.5%, 16.4%, and 18.0%, respectively, compared to the initial thermal resistance. From the test results according to the 70 °C heat acceleration test method specified in the EN 13166, the thermal resistance decreased by 2.0% for EPS, 6.7% for XPS, 8.7% for PF and 13.6% for PIR, compared to their respective initial thermal resistance values. The EPS showed highly similar thermal resistance changes for the two different test methods. It was found that there was no effect from the slicing of the insulation material, and the accelerated aging test showed minimal changes in thermal resistance. In contrast, the other insulation materials exhibited different thermal resistance changes depending on the test method, with each material showing a thermal resistance change of 8.8% to 15.9% when subjected to the accelerated aging test.
Suggested Citation
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:23:p:6105-:d:1536624. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.