Abstract

Virtual synchronous generator (VSG) control, which can provide inertia output, damp power oscillations, and offer frequency and voltage support to power grids, has become a growing trend in the control field of wind power generation. As a new technology, there are still challenges that VSG control has not solved well, such as transient overvoltage suppression. A kind of transient overvoltage, which often occurs during the commutation failures of HVDC transmission systems, will trigger a mass of wind turbine generators (WTGs) disconnecting from grids. To reduce the grid-disconnection risk of the virtual synchronous generator control-based doubly fed induction generators (VSG-DFIGs), this paper first analyzes the mechanism of the automatic voltage regulation (AVR) control usually employed by VSG-DFIGs, then proposes measures to suppress the transient overvoltage. To solve the problem of the reactive power response lag issued by VSG-DFIGs, which will further aggravate the transient overvoltage in continuous low and high voltage faults, the time constant of the AVR control is switched. To fully exploit the potential of the DFIGs’ reactive power support, the droop coefficient of the AVR control is switched during the abnormal voltage stages. The switched droop coefficient will change the rotor excitation current magnitude, thus adjusting the internal potential of a DFIG, finally better supporting or suppressing the terminal voltage during the low or high voltage periods. Simulation results based on the DIgSILENT/PowerFactory platform demonstrate that the proposed method can effectively suppress the transient overvoltage that occurs in continuous low and high voltage events caused by the commutation failures of HVDC transmission systems, reducing the number of WTGs disconnecting from the grids.

Suggested Citation

  • Shuyi Wang & Qicai Wang & Zhijie Zeng & Wei Jiang & Jinyu Chen & Zhijun Wang, 2024. "Overvoltage Suppression Strategy for VSG-Based DFIGs Under Commutation Failures of HVDC Transmission Systems," Energies, MDPI, vol. 17(23), pages 1-14, November.
  • Handle: RePEc:gam:jeners:v:17:y:2024:i:23:p:5989-:d:1531796
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/17/23/5989/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/17/23/5989/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:23:p:5989-:d:1531796. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.