IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v17y2024i21p5412-d1510190.html
   My bibliography  Save this article

Implementation of Fuzzy Logic Scheme for Assessment of Power Transformer Oil Deterioration Using Imprecise Information

Author

Listed:
  • Zuhaib Nishtar

    (College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, China)

  • Fangzong Wang

    (College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, China)

Abstract

This research aims to analyze the implementation of a fuzzy logic-based approach in improving the diagnosis of power transformer oil deterioration, which is critical for maintaining the efficient performance and operational life of transformers. Traditional diagnoses are based on strict measurements that do not account for the factors of variability and uncertainty of the actual data. In this article, we perform six different types of tests in this regard, and data have been collected during the period of 2021 to 2022 of 188 power transformer failures in the New KotLakhpat Lahore unit, whose voltage range is 132/66 kv and rating capacity is 40/50 MVA. In this case, a fuzzy logic-based scheme is developed based upon the membership function, a rule-based and defuzzification method that works with imprecision and the implementation of uncertainty in assessing the condition of transformer oils. Moisture, acidity, and a dissolved gas analysis indicator, along with other indication approaches such as interfacial tension, viscosity, and tangent delta measurement, are used to analyze the deterioration process in transformer oils. In the visual representation, oil samples with the following properties were first fuzzified: 19.9 mm 2 /s of viscosity, 0.453 mgKOH/g of acidity, 695 ppm of DGA, 20.8 mg/kg of moisture, 19.98 of IFT, and 4.35 × 10 0.14 of tangent delta. The output that was generated by software using the values entered into the parameters (HI and Age) after defuzzification is 45. Fuzzy logic serves as a concrete framework for transforming the diagnostics system and deterring the threats to the entire transformer’s health and reliability in the future. By using this technique, various faults were hypothetically and practically analyzed in a transformer to implement early detection technologies with the possibility to reduce maintenance costs and extend operational life up to 45 years. Various case studies indicate the effectiveness of fuzzy logic in comparison to traditional diagnostics.

Suggested Citation

  • Zuhaib Nishtar & Fangzong Wang, 2024. "Implementation of Fuzzy Logic Scheme for Assessment of Power Transformer Oil Deterioration Using Imprecise Information," Energies, MDPI, vol. 17(21), pages 1-20, October.
  • Handle: RePEc:gam:jeners:v:17:y:2024:i:21:p:5412-:d:1510190
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/17/21/5412/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/17/21/5412/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Zaijun Jiang & Xin Li & Heng Zhang & Enze Zhang & Chuying Liu & Xianhao Fan & Jiefeng Liu, 2024. "Research Progress and Prospect of Condition Assessment Techniques for Oil–Paper Insulation Used in Power Systems: A Review," Energies, MDPI, vol. 17(9), pages 1-36, April.
    2. J. Sanz & C. J. Renedo & A. Ortiz & P. J. Quintanilla & F. Ortiz & D. F. García, 2023. "A Brief Review of the Impregnation Process with Dielectric Fluids of Cellulosic Materials Used in Electric Power Transformers," Energies, MDPI, vol. 16(9), pages 1-24, April.
    3. Andrew Adewunmi Adekunle & Samson Okikiola Oparanti & Issouf Fofana, 2023. "Performance Assessment of Cellulose Paper Impregnated in Nanofluid for Power Transformer Insulation Application: A Review," Energies, MDPI, vol. 16(4), pages 1-32, February.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Wiktor Kunikowski & Pawel Rozga & Bartlomiej Pasternak & Jakub Staniewski & Filip Stuchala & Konrad Strzelecki, 2024. "Impact of Electrode Distance in a Quasi-Uniform Model Electrode System on Lightning Impulse Breakdown Voltage in Various Insulating Liquids," Energies, MDPI, vol. 17(4), pages 1-18, February.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:21:p:5412-:d:1510190. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.