IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v17y2024i18p4708-d1482639.html
   My bibliography  Save this article

Thermodynamic Comparative Analysis of Cascade Refrigeration System Pairing R744 with R404A, R448A and R449A with Internal Heat Exchanger: Part 2—Exergy Characteristics

Author

Listed:
  • Min-Ju Jeon

    (Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, 45, Yongso-ro, Nam-gu, Busan 48513, Republic of Korea)

  • Joon-Hyuk Lee

    (Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, 45, Yongso-ro, Nam-gu, Busan 48513, Republic of Korea)

Abstract

The cascade refrigeration systems (CRS) used in hypermarkets and supermarkets, which are used by many people, have been employing R744 for the low-temperature cycle (LTC) and R404A for the high-temperature cycle (HTC) due to environmental and public safety issues. However, the use of R404A is limited due to its high GWP, and therefore research on alternative refrigerants is necessary. Nevertheless, there is no detailed study in the literature that compares and analyzes the three refrigerants for practical design by applying R744 for LTC and R404A, R448A, and R449A for HTC in CRS. Therefore, this study aims to provide data for the practical detailed design of an alternative system to R744/R404A CRS. Under standard conditions, we analyzed how the exergy destruction rate (EDR) and exergy efficiency (EE) of the system and the EDR of each component change when the important factors affecting CRS (degree of superheating (DSH), degree of subcooling (DSC), and internal heat exchanger (IHX) efficiency of HTC, DSH of LTC, condensation temperature (CT), evaporation temperature (ET), cascade evaporation temperature (CET), and temperature difference of CHX) are varied over a wide range. The main conclusions are as follows. (1) Under the given constant conditions, the smallest change in system EDR based on R448A is DSH of HTC (decreased by 0.07–0.1 kW), followed by IHX of HTC (decreased by 0.12–0.3 kW), DSH of LTC (increased by 0.19–0.25 kW), DSC of HTC (decreased by 0.59–0.69 kW), temperature difference of CHX (increased by 1.57–1.83 kW), CET (decreased and then increased by 0.67–4.43 kW), CT (increased by 1.49–3.9 kW), ET (decreased by 2.39–4.61 kW). (2) The highest change rate of system EE based on R448A is CET (increased and then decreased by 1.38–8.28%), followed by temperature difference of CHX (decreased by 2.96–3.16%), ET (increased and then decreased by 0.63–2.75%), DSC of HTC (increased by 1.26–1.34%), CT (increased and then decreased by 0.24–1.12%), IHX of HTC (increased by 0.11–1.02%), DSH of LTC (decreased by 0.35–0.49%), and DSH of HTC (increased by 0.14–0.19%).

Suggested Citation

  • Min-Ju Jeon & Joon-Hyuk Lee, 2024. "Thermodynamic Comparative Analysis of Cascade Refrigeration System Pairing R744 with R404A, R448A and R449A with Internal Heat Exchanger: Part 2—Exergy Characteristics," Energies, MDPI, vol. 17(18), pages 1-23, September.
  • Handle: RePEc:gam:jeners:v:17:y:2024:i:18:p:4708-:d:1482639
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/17/18/4708/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/17/18/4708/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:18:p:4708-:d:1482639. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.