Author
Listed:
- Marzena Iwaniszyn
(Institute of Chemical Engineering, Polish Academy of Sciences, Bałtycka 5, 44-100 Gliwice, Poland)
- Mateusz Korpyś
(Institute of Chemical Engineering, Polish Academy of Sciences, Bałtycka 5, 44-100 Gliwice, Poland)
- Adam Rotkegel
(Institute of Chemical Engineering, Polish Academy of Sciences, Bałtycka 5, 44-100 Gliwice, Poland)
- Zenon Ziobrowski
(Institute of Chemical Engineering, Polish Academy of Sciences, Bałtycka 5, 44-100 Gliwice, Poland)
- Andrzej Kołodziej
(Institute of Chemical Engineering, Polish Academy of Sciences, Bałtycka 5, 44-100 Gliwice, Poland)
- Katarzyna Sindera
(Institute of Chemical Engineering, Polish Academy of Sciences, Bałtycka 5, 44-100 Gliwice, Poland)
- Mikołaj Suwak
(Institute of Chemical Engineering, Polish Academy of Sciences, Bałtycka 5, 44-100 Gliwice, Poland)
- Anna Gancarczyk
(Institute of Chemical Engineering, Polish Academy of Sciences, Bałtycka 5, 44-100 Gliwice, Poland)
Abstract
A new type of compact, portable fixed-bed reactor integrated with a heat transfer system was developed for the removal of volatile and flammable air pollutants such as lean methane and volatile organic compounds (VOCs). The reactor may operate in catalytic or thermal combustion conditions with the purpose of achieving autothermal processes with the possibility of energy recovery. An excess heat recovery point was designed behind the reactor bed at the place where the gas temperature is the highest to enable its usage. The mathematical model is presented together with a number of simulation calculations performed for the assessment of the developed reactor. The case study in this paper was for catalytic methane oxidation at a temperature of 400 °C, a methane concentration between 0.1% and 2% by weight, a gas flow rate of 1 m 3 /s STP, and a heat exchange surface for the assumed plate exchanger from 10 to 200 m 2 . The calculations show that the thickness of the insulation is of little importance for the operation of the equipment, and a sufficient thickness was about 20–50 mm. The optimal area for the considered case is 80–100 m 2 . It was found that recovery of thermal energy is possible only for higher methane concentrations, above 0.3% by weight. Using an appropriate surface for the exchanger, it is possible to recover even 50% of the combustion enthalpy at a methane concentration of 0.45% by weight. For an exchanger area below 50 m 2 , the recoverable energy drops rapidly. It was found that the exchanger area is the most important equipment parameter under consideration.
Suggested Citation
Marzena Iwaniszyn & Mateusz Korpyś & Adam Rotkegel & Zenon Ziobrowski & Andrzej Kołodziej & Katarzyna Sindera & Mikołaj Suwak & Anna Gancarczyk, 2024.
"Innovative Fixed-Bed Reactor Integrated with Heat Transfer System for Lean Methane Mixture Removal,"
Energies, MDPI, vol. 17(17), pages 1-11, September.
Handle:
RePEc:gam:jeners:v:17:y:2024:i:17:p:4408-:d:1470261
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:17:p:4408-:d:1470261. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.