Abstract
The active power losses are dependent on the flowing electric power value through overhead and cable lines. The current flow through the conductor causes negative phenomena to occur, such as released heat. The source of the current harmonics is the non-linear loads. Hence, the skin effect occurs, and the current carrying capacity of cables is reduced. This results in the increase in and uneven distribution of the temperature inside the conductor. This paper presents a comparison of the temperature distribution inside a power cable for an ideal 50 Hz sine wave and highly distorted current ( T H D I = 41 % ) . The calculated active power losses for the IEC 60287-1-1:2006+A1:2014 standard and the method described in the literature were used as a basis for further calculations. The obtained results revealed the problem of the uneven distribution of the conductor temperature. Considering the skin effect, increasing the temperature in the outer layers leads to severe damage and faster insulation aging. The abovementioned phenomenon is a decrease in the permissible load capacity of the conductor. The table given in the IEC 60364-5-52 standard summarizes the percentage contribution of the third harmonic to the current waveform. For percentages between 15% and 33%, the current carrying capacity is reduced by up to 86% of the full-load current rating. In addition, consideration of thermal conditions forces the use of cables with larger cross-sections. This leads to their non-optimal use and makes the investment more expensive from an economic point of view.
Suggested Citation
Natalia Radwan-Pragłowska & Dominik Mamcarz & Paweł Albrechtowicz & Bartosz Rozegnał, 2024.
"The Current Harmonic Impact on Active Power Losses and Temperature Distribution in Power Cables,"
Energies, MDPI, vol. 17(16), pages 1-18, August.
Handle:
RePEc:gam:jeners:v:17:y:2024:i:16:p:4170-:d:1460931
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:16:p:4170-:d:1460931. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.