Abstract
Road lighting is one of the most important services provided by public entities. Entities providing such a service are interested in providing it with the lowest possible financial outlays. When planning modernization, unfortunately, one forgets about hidden operating costs, which are caused by, among others, the flow of reactive energy in the circuit. The use of modern light sources also involves the use of electronic systems in their accessories, which makes these electrical energy receivers capacitive. This is due to the lack of use of individual compensation systems in the luminaires themselves. Due to the above, the costs of capacitive reactive energy flow also increase. Newly designed road lighting installations, as well as modernized ones, are equipped with electronic systems enabling their effective control. The operation of such systems also causes fluctuations in the reactive power value, which must be compensated. Commonly used compensation choke systems also introduce additional active power losses, which makes the expected savings lower than expected. In the article, the authors presented selected results of measurements of the electrical parameters of LED luminaires, carried out both in the laboratory and in used road lighting circuits. The determined amounts of active power losses caused by the installation and operation of additional equipment in the road lighting installation, such as compensating chokes, are presented. The calculations were made based on the example of a selected fragment of the audit of this installation. On this basis, modernization was carried out and measurements of current electricity quality parameters were carried out.
Suggested Citation
Marek Kurkowski & Tomasz Popławski & Maciej Zajkowski & Zbigniew Sołjan, 2024.
"The Impact of Limiting Reactive Power Flows on Active Power Losses in Lighting Installations,"
Energies, MDPI, vol. 17(16), pages 1-18, August.
Handle:
RePEc:gam:jeners:v:17:y:2024:i:16:p:4072-:d:1457527
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:16:p:4072-:d:1457527. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.