Author
Listed:
- Zheng Shi
(Economic and Technical Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030000, China)
- Haixiao Zhu
(School of Electrical and Power Engineering, Taiyuan University of Technology, Taiyuan 030024, China)
- Haibo Zhao
(Economic and Technical Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030000, China)
- Peng Wang
(Economic and Technical Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030000, China)
- Yan Liang
(Economic and Technical Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030000, China
School of Electrical and Electronic Engineering, North China Electric Power University, Beijing 100000, China)
- Kaikai Wang
(Economic and Technical Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030000, China)
- Jie Chen
(Economic and Technical Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030000, China)
- Xiaoming Zheng
(Economic and Technical Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030000, China)
- Hongli Liu
(Economic and Technical Research Institute of State Grid Shanxi Electric Power Company, Taiyuan 030000, China)
Abstract
In adapting to the double-high development trend of high-voltage direct current (HVDC) receiving-end power systems and solving optimization problems in emergency frequency control (EFC) supporting virtual power plants (VPPs) in large-scale power systems, a parameter estimation method for a VPP frequency response model based on a successive linear programming (SLP) method is proposed. First, a “centralized/decentralized” hierarchical control architecture for VPP participation in EFC is designed. Second, the frequency response characteristics of multiple flexible resources are scientifically analyzed, and the system frequency response (SFR) model and equivalent model of VPP are constructed. Subsequently, parameter estimation of the VPP frequency response model is carried out based on the SLP method, aiming to balance the accuracy and computational efficiency of the model. Finally, the effectiveness of the proposed methodology is verified by using PSD-BPA to simulate and test the three-zone HVDC recipient area grid.
Suggested Citation
Zheng Shi & Haixiao Zhu & Haibo Zhao & Peng Wang & Yan Liang & Kaikai Wang & Jie Chen & Xiaoming Zheng & Hongli Liu, 2024.
"Parameter Estimation Method for Virtual Power Plant Frequency Response Model Based on SLP,"
Energies, MDPI, vol. 17(13), pages 1-15, June.
Handle:
RePEc:gam:jeners:v:17:y:2024:i:13:p:3124-:d:1421718
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:13:p:3124-:d:1421718. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.